 Table of input terminal functions 3
Function
Code
No.
96
FRR
Coast stop command
97
FRRN
Inversion of coast stop command
98
FR
Forward/reverse selection
99
FRN
Inversion of forward/reverse selection
100
RS
Run/Stop command
101
RSN
Inversion of run/Stop command
104
FCHG
Frequency setting mode forced switching
105
FCHGN
Inversion of frequency setting mode forced
switching
106
FMTB
Frequency setting mode terminal board
107
FMTBN
Inversion of frequency setting mode terminal
board
108
CMTB
Command mode terminal board
109
CMTBN
Inversion of command mode terminal board
110
PWE
Parameter editing permission
111
PWEN
Inversion of parameter editing permission
120
FSTP1
Fast stop command 1
121
FSTP1N
Inversion of fast stop command 1
122
FSTP2
Fast stop command 2
123
FSTP2N
Inversion of fast stop command 2
134
TVS
Traverse permission signal
135
TVSN
Inversion of traverse permission signal
136, 137
Factory specific coefficient
140
SLOWF
Forward deceleration
141
SLOWFN
Inversion of forward deceleration
142
STOPF
Forward stop
143
STOPFN
Inversion of forward stop
144
SLOWR
Reverse deceleration
145
SLOWRN
Inversion of reverse deceleration
146
STOPR
Reverse stop
147
STOPRN
Inversion of reverse stop
148 to 151
Factory specific coefficient
200
PWP
Parameter editing prohibition
201
PWPN
Inversion of parameter editing prohibition
PRWP
Parameter reading prohibition
202
203
PRWPN
Inversion of parameter reading prohibition
*1: Factory specific coefficient parameters are manufacturer setting parameters. Do not change the value of these parameters.
Note 1: Function No. that are not described in the table above are assigned "No function".
Function
ON: Coast stop (Gate OFF)
OFF: Coast stop canceled
Inversion of FRR
ON: Forward operation command
OFF: Reverse operation command
Inversion of FR
ON: Run command
OFF: Stop command
Inversion of RS
ON: f207 (f200=0)
OFF: fmod
Inversion of FCHG
ON: Terminal board (VIA) enabled
OFF: Setting of 
Inversion of FMTB
ON: Terminal board enabled
OFF: Setting of 
Inversion of CMTB
ON: Parameter editing permitted
OFF: Setting of 
Inversion of PWE
ON: Dynamic quick deceleration command
OFF: Forced deceleration canceled
(Note that operation is resumed when forced deceleration is
canceled)
Inversion of FSTP1
ON: Automatic deceleration
OFF: Forced deceleration canceled
(Note that operation is resumed when forced deceleration is
canceled)
Inversion of FSTP2
ON: Permission signal of traverse operation
OFF: Normal operation
Inversion of TVS
ON: Forward operation with f383 frequency
OFF: Normal operation
Inversion of SLOWF
ON: Forward stop
OFF: Normal operation
Inversion of STOPF
ON: Reverse operation with f383 frequency
OFF: Normal operation
Inversion of SLOWR
ON: Reverse stop
OFF: Normal operation
Inversion of STOPR
ON: Parameter editing prohibited
OFF: Setting of 
Inversion of PWP
ON: Parameter reading / editing prohibited
OFF: Setting of 
Inversion of PRWP
K-33
E6581697
Action
-
-
Reference
3.2.1
7.2.1
7.2.1
5.6
6.29.1
5.4.1
6.35
*1
6.18.2
11
*1
6.29.1

Hide quick links: