Toshiba TOSVERT VF-MB1 Instruction Manual page 313

Industrial inverter for 3-phase induction motors
Hide thumbs Also See for TOSVERT VF-MB1:
Table of Contents

Advertisement

Communication
Title
Function
No.
0810
Communication

command point
selection
0811
Communication

command point 1
setting
0812
Communication

command point 1
frequency
0813
Communication

command point 2
setting
0814
Communication

command point 2
frequency
0829
Selection of

communication
protocol
0856
Number of motor

poles for
communication
0870
Block write data 1

0871
Block write data 2

0875
Block read data 1

0876
Block read data 2

0877
Block read data 3

0878
Block read data 4

0879
Block read data 5

0880
Free notes

0898
Factory specific

coefficient 8A
0899
Communication

function reset
*1: Default setting values vary depending on the setup menu setting. Refer to section 11.5.
*3: Factory specific coefficient parameters are manufacturer setting parameters. Do not change the value of these parameters.
Minimum
setting unit
Unit
Adjustment range
Panel/Commun
ication
-
1/1
0: Disabled
1: Enabled
%
1/1
0-100
Hz
0.1/0.01
0.0-
%
1/1
0-100
Hz
0.1/0.01
0.0-
-
-
0: Toshiba inverter protocol
1: Modbus RTU protocol
-
-
1: 2 poles
2: 4 poles
3: 6 poles
4: 8 poles
5: 10 poles
6: 12 poles
7: 14 poles
8: 16 poles
-
-
0: No selection
1: Command information 1
2: Command information 2
3: Frequency command value
-
-
4: Output data on the terminal board
5: Analog output for communication
6: Speed command value
-
-
0: No selection
1: Status information
2: Output frequency
3: Output current
-
-
4: Output voltage
5: Alarm information
6: PID feedback value
-
-
7: Input terminal board monitor
8: Output terminal board monitor
9: VIA terminal board monitor
-
-
10: VIB terminal board monitor
11: VIC terminal board monitor
12: Input voltage (DC detection)
-
-
13: Motor speed
14: Torque
-
1/1
0-65530 (65535)
-
-
-
-
-
0: -
1: Reset (after execution: 0)
K-25
E6581697
Default
User
Reference
setting
setting
0
6.6.2
6.33.1
0
0.0
100
*1
0
6.33.1
2
0
0
0
0
0
0
0
0
6.33.3
-
*3
0
6.33.1
11