To Test Heater Assembly (Electric Models); Front Air Duct - ALLIANCE AE9133 Service Manual

Ae/ag/ne/ng series home laundry dryers
Table of Contents

Advertisement

Section 5 Service Procedures
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the dryer(s) before servicing.
• Close gas shut-off valve to gas dryer(s) before servicing.
• Never start the dryer(s) with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the dryer is properly grounded.

To Test Heater Assembly (Electric Models)

1. Disconnect wires from heater assembly.
NOTE: Refer to appropriate wiring diagram
when rewiring heater assembly.
2. Set meter to read Ohms. Apply meter probes to
the heater assembly terminals. Meter should
read 10.4 Ohms ± .30 Ohms cold.

45. FRONT AIR DUCT

a. Remove two screws from the bottom edge of
the front panel. Refer to Figure 12.
b. Swing the bottom of the panel away from the
dryer to disengage hold-down clips and guide
lugs from cabinet top. Refer to Figure 12.
c. Disconnect wires from door switch. Refer to
Figure 13.
NOTE: Refer to the appropriate wiring diagram
when rewiring the switch.
d. Remove lint filter out of front air duct. Refer to
Figure 10.
NOTE: When installing lint filter, be sure to install
the filter with the words "FRONT" facing the front
of the dryer.
e. Remove four screws holding air duct to front
bulkhead and remove air duct. Refer to
Figure 21.
NOTE: When reassembling, be sure felt seal on
exhaust fan cover makes air tight seal on flange of
duct. Refer to Figure 20.
38
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
WARNING
HEX
HEAD
SCREWS
SLOT
CABINET TOP
HOLD-DOWN
SCREWS
PHILLIPS HEAD
SCREWS
DRY858S
CABINET
ATTACHING SCREWS
Figure 21
W001R1
FRONT
BULKHEAD
HEX
HEAD
SCREWS
SLOT
AIR
DUCT
DRY858S
60549

Advertisement

Table of Contents
loading

Table of Contents