Symptom: "Op" Appears In Time Display - ALLIANCE AE9133 Service Manual

Ae/ag/ne/ng series home laundry dryers
Table of Contents

Advertisement

To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the dryer(s) before servicing.
• Close gas shut-off valve to gas dryer(s) before servicing.
• Never start the dryer(s) with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the dryer is properly grounded.

85. SYMPTOM: "oP" APPEARS IN TIME DISPLAY

Unplug power cord, remove front
panel and check for broken, loose
or incorrect wiring between
thermistor and control.
Wiring between terminals "P5"
and "P6" on control and the
thermistor terminals okay?
Remove wires from thermistor
and take resistance reading
across the thermistor terminals.
Did you read infinite Ohms?
Was temperature near thermistor
below 30°F? For safety purposes,
the control will go into the "oP"
condition if the temperature near
the thermistor falls below 30° F.
Reconnect wires to thermistor
and plug in power cord. Press
REGULAR and GO pads to start
dryer. The dryer will heat for three
minutes to raise the temperature
above 30° F.
Did "oP" appear in display after
three minutes.
Recheck from beginning. If
problem persists, always replace
thermistor before replacing the
control.
60549
Section 8 Service Procedures Unique to Electronic Control Model Dryers
YES
NO
YES
YES
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
WARNING
NO
Refer to wiring diagram
and correct.
YES
Replace thermistor.
NO
Replace thermistor.
NO
Normal operation.
W001R1
87

Advertisement

Table of Contents
loading