To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the dryer(s) before servicing.
• Close gas shut-off valve to gas dryer(s) before servicing.
• Never start the dryer(s) with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the dryer is properly grounded.
TOP VIEW OF
GAS VALVE
BURNER
ORIFICE
SPUD
VENT
SCREW
APPLY NO. 60517
VALVE CONVERTED
STICKER HERE
Figure 42
(4) Stop dryer and remove "U " tube and
reinstall the pressure tap pipe plug. Refer to
Figure 41 .
m. Check the gas line connection for gas leaks with
a soapy solution.
60549
CLOSED
POSITION
OPEN
POSITION
APPLY NO. 60520
L.P. GAS STICKER
HERE
DRY964S
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Section 7 Gas Burner Conversion Procedures
WARNING
SHUT-OFF
VALVE HANDLE
VENT
SCREW
PRESSURE TAP
PIPE PLUG
Figure 41
To reduce the risk of an explosion or fire,
do not use an open flame to check for gas
leaks!
n. Make sure the dryer conversion has been
completed. Recheck the following:
(1) Installed correct orifice spud (#55), see
step "e".
(2) Installed block-open plug, see step "g".
(3) Gas valve pressure must be 10 ± 1.5 inches
(25.4 ± 3.8 cm), see step "l".
(4) Installed four stickers, see steps "h", "i",
and "j".
o. Start dryer and observe burner flame. Adjust air
shutter to obtain a soft, uniform flame. (A lazy,
orange tipped flame indicates lack of air. A
harsh, roaring, very blue flame indicates too
much air.) Adjust air shutter to obtain a soft
uniform blue flame as follows:
IGNITER QUICK
DISCONNECT BLOCKS
BURNER
HOUSING
DRY963S
DANGER
W001R1
BURNER
TUBE
HEX HEAD
SCREW
AIR
SHUTTER
59