ALLIANCE CHD25G2-CA025L Installation Operation & Maintenance

25 pound (11,3 kilogram) capacity 30 pound (13,6 kilogram) capacity 35 pound (16 kilogram) capacity stacked 30 pound (13,6 kilogram) capacity stacked 45 pound (20,4 kilogram) capacity 55 pound (25 kilogram) capacity
Table of Contents

Advertisement

Tumble Dryers
25 Pound (11,3 Kilogram) Capacity
30 Pound (13,6 Kilogram) Capacity
35 Pound (16 Kilogram) Capacity
Stacked 30 Pound (13,6 Kilogram) Capacity
Stacked 45 Pound (20,4 Kilogram) Capacity
55 Pound (25 Kilogram) Capacity
Original Instructions
Keep These Instructions for Future Reference.
(If this machine changes ownership, this manual must accompany machine.)
Starting Serial No. 0602004144
Refer to Page 6 for Model Identification
T477C
www.alliancelaundry.com
T478C
Part No. 70458301ENR6
June 2013

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the CHD25G2-CA025L and is the answer not in the manual?

Questions and answers

Summary of Contents for ALLIANCE CHD25G2-CA025L

  • Page 1 Tumble Dryers 25 Pound (11,3 Kilogram) Capacity 30 Pound (13,6 Kilogram) Capacity 35 Pound (16 Kilogram) Capacity Stacked 30 Pound (13,6 Kilogram) Capacity Stacked 45 Pound (20,4 Kilogram) Capacity 55 Pound (25 Kilogram) Capacity Starting Serial No. 0602004144 Refer to Page 6 for Model Identification T477C T478C Original Instructions...
  • Page 3 IMPORTANT: The installer must fully test the tumble dryer after installation and demonstrate to the owner how to operate the machine. 70458301ENR6 © Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT...
  • Page 4 A “T-Handle” type gas shut-off valve must be installed in the gas supply line to this appliance.  This appliance must not be installed in a bedroom or bathroom. © Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT 70458301ENR6...
  • Page 5: Table Of Contents

    All rights reserved. No part of the contents of this book may be reproduced or transmitted in any form or by any means without the expressed written consent of the publisher. 70458301ENR6 © Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT...
  • Page 6 Proper Electrode Location ............... 95 Flame Current Measurement............95 Ignition Control Operation for Non-CE Models Through 3/10/13............96 Ignition Control Operation for CE Models Through 3/10/13.............. 97 © Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT 70458301ENR6...
  • Page 7 Annually ....................102 Fire Suppression System Maintenance Test ........103 Before You Call for Service ............... 105 Removing Tumble Dryer from Service..........105 Disposal of Unit ................... 106 70458301ENR6 © Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT...
  • Page 8: Introduction

    CKT30N HUT30N UAT30N IPD30STE2 DR335 IPD30STG2 UKT30N Series DR335G2-BKT30N ITT30L UTT30L DRST30G2-BAT30L ITT30N UTT30N DRST30G2-BAT30N MTT30N UUT30L DRST30G2-BTT30D NTT30N UUT30N DRST30G2-BTT30L SAT30L DRST30G2-BTT30N SAT30N DRST30G2-BUT30L DRST30G2-BUT30N (Continued) 70458301ENR6 © Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT...
  • Page 9 HU055N UT055L Not Applicable Series DR55SG2-BA055N IPD55G2 UT055N DR55SG2-BK055N IT055L UU055L DR55SG2-BT055D IT055N UU055N DR55SG2-BT055L SA055L DR55SG2-BT055N SA055N DR55SG2-BU055L SK055N DR55SG2-BU055N ST055D (see next page for suffixes) 70458301ENR6 © Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT...
  • Page 10 NY – NetMaster, prep for card coin KB – reversing single coin OM – OPL micro ZY – NetMaster network, prep for KC – single coin QT – dual digital timer card 70458301ENR6 © Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT...
  • Page 11: Contact Information

    Model Number ______________________________ Serial Number _______________________________ Please include a copy of your bill of sale and any service receipts you have. TMB2098N TMB1974N TMB1974N Serial Plate Figure 1 70458301ENR6 © Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT...
  • Page 12: Safety Information

    “NOTE”) are followed by specific instructions. IMPORTANT: The word “IMPORTANT” is used to inform the reader of specific procedures where minor machine damage will occur if the procedure is not followed. 70458301ENR6 © Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT...
  • Page 13: Important Safety Instructions

    7. Do not use or store flammable materials near this 17. Remove laundry immediately after tumble dryer appliance. stops. 70458301ENR6 © Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT...
  • Page 14 Be sure make-up air is free of solvent vapors. 70458301ENR6 © Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT...
  • Page 15: Specifications And Dimensions

    (134,700) (134,700) (166,000) (recommended operating pressure 80-100 psig) N/A = Not Applicable NOTE: All machines are shipped with extra nipple to convert to metric thread (from Standard). 70458301ENR6 © Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT...
  • Page 16 * with both pockets running ** for each pocket N/A = Not Applicable NOTE: All machines are shipped with extra nipple to convert to metric thread (from Standard). 70458301ENR6 © Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT...
  • Page 17: Cabinet Dimensions - 025, 030, 035 And 055 Series

    * Fire suppression system optional - may not be on machine. NOTE: Facia panels available to increase height of models to 72.25 inches (1,835 mm) and 76.25 inches (1,938 mm). 70458301ENR6 © Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT...
  • Page 18: Cabinet Dimensions - T30 And T45 Series

    T45 Series (746 mm) (1,235 mm) (775 mm) (876 mm) (2,063.75 mm) NOTE: To meet ADA compliance, install a 4 inch (102 mm) riser on T30 models only. 70458301ENR6 © Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT...
  • Page 19: Exhaust Outlet Locations - 025, 030, 035 And 055 Series

    8 in. 4.875 in. 5.625 in. 035 Series (203 mm) (124 mm) (143 mm) 8 in. 4.808 in. 6.156 in. 055 Series (203 mm) (122 mm) (156.3 mm) 70458301ENR6 © Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT...
  • Page 20: Exhaust Outlet Locations - T30 And T45 Series

    Fits 8 in. (203 mm) (928 mm) (108 mm) (1,585 mm) Elliptical 40.88 in. 4.75 in. 66.00 in. T45 Series Fits 10 in. (254 mm) (1,038 mm) (121 mm) (1,676 mm) 70458301ENR6 © Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT...
  • Page 21: Gas Connection Locations - 025, 030, 035 And 055 Series

    57 in. 4 in. 43 in. 35 Series (1,450 mm) (101.6 mm) (1,092 mm) 55.285 in. 1.621 in. 46.75 in. 55 Series (1,404 mm) (41.17 mm) (1,187.45 mm) 70458301ENR6 © Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT...
  • Page 22: Gas Connection Locations - T30 And T45 Series

    75.28 in. 2.5 in. 30.60 in. Australian (1,912 mm) (64 mm) (777 mm) 78.75 in. 4.12 in. 42.88 in. T45 Series (2,000 mm) (105 mm) (1,089 mm) 70458301ENR6 © Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT...
  • Page 23: Electrical Connection Locations - 025, 030, 035 And 055 Series

    035 Series (1,581 mm) (76 mm) (711 mm) (108 mm) 65.187 in. 1.765 in. 32.526 in. 6.547 in. 055 Series (1,655.75 mm) (44.83 mm) (826.16 mm) (166.3 mm) 70458301ENR6 © Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT...
  • Page 24: Electrical Connection Locations - T30 And T45 Series

    2.28 in. T30 Series (1,498 mm) (44 mm) (905 mm) (1,859 mm) (58 mm) 62.5 in. 1.75 in. T45 Series (1,588 mm) (44 mm) N/A = Not Applicable 70458301ENR6 © Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT...
  • Page 25: Steam Connection Locations - 025, 030 And 035 Series

    Models 53.75 in. 6.29 in. 42.5 in. 2.39 in. 025/030/035 Series (1,365 mm) (160 mm) (1,080 mm) (61 mm) NOTE: All connections use 3/4 in. NPT pipe. 70458301ENR6 © Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT...
  • Page 26: Steam Connection Locations - T30 Series

    36.35 in. 6.29 in. 25.13 in. 2.39 in. T30 Series (Lower) (923 mm) (160 mm) (638 mm) (61 mm) NOTE: All connections use 3/4 in. NPT pipe. 70458301ENR6 © Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT...
  • Page 27: Installation

    A typical tumble dryer enclosure is shown in Figure 2. IMPORTANT: Install tumble dryers with sufficient clearance for servicing and operation, refer to Figure 2. 70458301ENR6 © Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT...
  • Page 28 24 in. (610 mm) minimum, 36 in. (914 mm) recommended for maintenance purposes. Provision for make-up air. 0.25 in. (6 mm) recommended for removal or installation purposes, zero clearance allowed. Figure 2 70458301ENR6 © Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT...
  • Page 29: Position And Level The Tumble Dryer

    IMPORTANT: Keep tumble dryer as close to floor as possible. The unit must rest firmly on floor so weight of tumble dryer is evenly distributed. T467I Fifth Leg Figure 4 T483I T483I Figure 3 70458301ENR6 © Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT...
  • Page 30: Fire Suppression System

    Water Solenoid Valve Figure 5 To connect the two hoses (supplied with tumble dryer), insert rubber washers (from literature pack) in water inlet hose couplings. Refer to Figure 6. 70458301ENR6 © Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT...
  • Page 31: Electrical Requirements

    IMPORTANT: Hoses and other natural rubber parts deteriorate after extended use. Hoses may develop cracks, blisters or material wear from the temperature and constant high pressure they are subjected to. 70458301ENR6 © Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT...
  • Page 32: Auxiliary Alarm

    Light TMB2100N Reset Button TMB2100N Front Panel Screw Auxiliary Alarm Fast-On Connection Front Panel Control Panel Figure 7 Control Assembly Screw Control Assembly Lint Panel Figure 8 70458301ENR6 © Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT...
  • Page 33 Door Assembly Side Screw TMB2109N Beginning Location of Door Switch Harness Figure 9 Wire Ties Original Switch Location Panel Cutout Top Panel Original Plug Location Figure 10 70458301ENR6 © Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT...
  • Page 34 Door Assembly Tumble Dryer should not start with door open; an Side Screw operating tumble dryer should stop when door is opened. Figure 11 70458301ENR6 © Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT...
  • Page 35: Before Placing Tumble Dryer Into Service

    TMB2104N Wire Tie Figure 12 4. Turn on electrical supply to tumble dryer. 5. Open the supply valve for gas or steam heated tumble dryers. 70458301ENR6 © Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT...
  • Page 36 3 door Australian times) 025, 030, 035, 055: Press reset button on rear of machine Australia T30, T45: Press lighted reset button in rear contactor (Continued) 70458301ENR6 © Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT...
  • Page 37: Required For Ce Models Only

    Figure 13 If the tumble dryer does not meet ANY of the listed requirements, remove tumble dryer from use. Refer to Removing Tumble Dryer from Service section. 70458301ENR6 © Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT...
  • Page 38: Installing Ce Gas Tumble Dryer

    For L.P. Gas, third family B/P at 50 mbar (5 kPa), order Regulated Natural Gas machines and convert according to Table 1. 70458301ENR6 © Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT...
  • Page 39: Ce Orifices

    M406361 3.7/5.0) 0.0935 M403017 0.1200 M401017 0.0820 M401027 0.0866 70070906 11.25/14.9 0.0866 70070906 G30 /G31 (28/37, 3+/3P regulated 0.0980 M406361 2.8/3.7) 0.0935 M403017 0.1200 M401017 Table 1 70458301ENR6 © Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT...
  • Page 40: Properties Of Ce Gases

    2,164 80.58 3,117 116.09 2,345 87.33 3,378 125.81 2.075 Pure Butane Third Pure Propane 1,898 70.69 2,363 2,063 76.83 2,568 95.65 1.55 LPG with Propane Table 2 70458301ENR6 © Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT...
  • Page 41: Basic Configuration

    4. For 025 Series Natural Gas models, L.P. Gas only. Install 025 Series L.P. orifice plate (Part No. 70201901) onto gas valve bracket. Refer to Figure 15. 5. Commission tumble dryer for use. 70458301ENR6 © Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT...
  • Page 42 Regulator Adjusting Housing and Gasket Manometer (Regulated version shown) Connect Over Loosened Slotted Pressure Tap Gas Valve Bracket Screw in Bottom of Gas Valve Spud Holder Figure 15 70458301ENR6 © Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT...
  • Page 43 Refer to Figure 15. NOTE: Blank burner orifices are Part No. 5. Commission tumble dryer for use. M400995. BURNER ORIFICE TMB2015N Size Stamped on Orifice Figure 16 70458301ENR6 © Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT...
  • Page 44: Exhaust Requirements

    288 in. (18,560 mm T45 Series Make-up air openings with louvers will restrict airflow. The opening must be increased to compensate for area taken up by louvers. 70458301ENR6 © Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT...
  • Page 45: Individual Venting

    20 feet (6.1 m). Cross section area of a rectangular duct must be increased by 20% for each additional 20 feet (6.1 m). Refer to Table 3 to determine equivalent venting. 70458301ENR6 © Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT...
  • Page 46 Consult your local building code for regulations which dryers. may also apply. NOTE: Where exhaust duct pierces a combustible wall or ceiling, the opening must be sized per local codes. 70458301ENR6 © Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT...
  • Page 47: Manifold Venting

    Figure 18 Static back pressure must be measured with all tumble dryers vented into the collector operating. 70458301ENR6 © Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT...
  • Page 48 NOTE: Table 4 represents units with the same vent size. If multiple vent sizes are used, consult a local HVAC specialist. NOTE: Duct clean-out recommended every 6 feet (183 cm). 70458301ENR6 © Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT...
  • Page 49 TWO MANIFOLD ASSEMBLIES TMB2018N Outlet duct diameter = combined largest duct 45° typical diameter of both sides Figure 20 Refer to Table 4 for measurements for each manifold. 70458301ENR6 © Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT...
  • Page 50: Gas Requirements

    W062R1 excess of 0.5 psig (34.5 mbar, 3.45 kPa). 70458301ENR6 © Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT...
  • Page 51 Tumble Dryers section, the above data does not apply Gas Supply Piping System to the CE. 6 in. (152 mm) Minimum Gas Pipe Gas Pipe Cap Sediment Trap Figure 21 70458301ENR6 © Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT...
  • Page 52: Gas Supply Pipe Sizing And Looping

    IMPORTANT: Gas loop piping must be installed as illustrated to equalize gas pressure for all tumble dryers connected to single gas service. Other gas using appliances should be connected upstream from loop. Figure 22 70458301ENR6 © Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT...
  • Page 53 3.5 (88.90) 4 (101.60) For L.P. Gas, correct the total Btu/hr by multiplying it by 0.6. The answer is the equivalent Btu on the above chart. Table 5 70458301ENR6 © Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT...
  • Page 54: High Altitude Burner Orifice Sizing

    0.1040 M411375 168,400 6,001-8,000 1,831-2,440 0.1015 M411376 155,000 8,001-10,000 2,441-3,050 0.0980 M406361 142,600 *Btu/hr. derate of 4% per 1,000 feet (305 meters) of altitude. Table 6 (continued) 70458301ENR6 © Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT...
  • Page 55 1,221-1,830 0.1142 M401022 99,027 6,001-8,000 1,831-2,440 0.1102 M402487 93,838 8,001-10,000 2,441-3,050 0.1063 M411375 87,630 *Btu/hr. derate of 4% per 1,000 feet (305 meters) of altitude. Table 6 70458301ENR6 © Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT...
  • Page 56: Electrical Requirements

    On a three phase portion of the electrical data on the serial plate. machine, if there is a “High Leg” or “Stinger Leg” it should be connected to W069 70458301ENR6 © Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT...
  • Page 57: Grounding Instructions

    NOTE: Activation of the emergency stop switch stops all machine control circuit functions, but DOES NOT remove all electrical power from machine. 70458301ENR6 © Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT...
  • Page 58: Service/Ground Location

    NOTE: Do not make service connections in control tray. TMB2128N Gas or Steam Models Series Through Terminal Block Ground Screw 7/31/11 TMB2129N Ground Electric Power Distribution Block Series Models Through 7/31/11 TMB2130N Figure 23 70458301ENR6 © Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT...
  • Page 59 Model Ground and Terminal Block Locations Non-CE Series Power Distribution Ground TMB2377N Block TMB2377N Control Tray Series Power Distribution Ground TMB2379N Block Control Tray TMB2379N Figure 24 70458301ENR6 © Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT...
  • Page 60 Power Disconnect POWER DISTRIBUTION BLOCK 13 NO 21 NC A1 LC1D32 Models Through 7/31/11 14 NO 22 NC A2 Electric Series Power Distribution Block TMB2115N TMB2115N Figure 25 70458301ENR6 © Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT...
  • Page 61: To Connect Electrical Service To The Tumble Dryer

    NOTE: Electric models are not field convertible conductor amperage required per unit. and must be connected to service specified on serial plate. 70458301ENR6 © Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT...
  • Page 62: Conversion Instructions

    3. Sign and date conversion sticker located on back of tumble dryer. 4. Follow the instructions covered in Connecting Electrical Service section. 70458301ENR6 © Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT...
  • Page 63 3. Sign and date conversion sticker located on back of tumble dryer. 4. Follow the instructions covered in Connecting Electrical Service section. 70458301ENR6 © Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT...
  • Page 64: Ferrite Ring Installation (025, 030, 035 And 055 Series Only)

    TMB2096N Ferrite Ring Electrical Connections V.A.C. Ground Wire Figure 26 70458301ENR6 © Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT...
  • Page 65: Electrical Specifications

    14 (2.5) 460-480V/60Hz/3ph 3 Phase machines should not have fuses, breakers only. ** Special low Amp blower model, 025 Series only. N/A = Not Applicable Table 8 70458301ENR6 © Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT...
  • Page 66 10A* – 3 pole 14 (2.5) 440V/60Hz/3ph L1, L2, L3, and ground 10A* – 3 pole 14 (2.5) 460-480V/60Hz/3ph 3 Phase machines should not have fuses, breakers only. Table 10 70458301ENR6 © Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT...
  • Page 67 L1, L2, L3, and ground 25A* – 3 pole 10 (6) 460-480V/60Hz/3ph 3 Phase machines should not have fuses, breakers only. N/A = Not Applicable Table 13 70458301ENR6 © Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT...
  • Page 68 These serial plate voltages are only options available on the T30 electric models. Current (Amp) is for one pocket only. ** Per heater on T30 electric models, each has two heaters. Table 15 70458301ENR6 © Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT...
  • Page 69 L1, L2, L3, and ground 50A* – 3 pole 8 (10) 400-415V/50Hz/3ph 3 Phase machines should not have fuses, breakers only. N/A = Not Applicable Table 17 70458301ENR6 © Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT...
  • Page 70: Steam Requirements

     Install union and shut-off valve in return line and make final pipe connections to return header. NOTE: To prevent water hammering, route return lines below outlets of steam coils. 70458301ENR6 © Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT...
  • Page 71: Installing Steam Trap And Making Condensate Return Connections

    4. Install a shut-off valve to each steam trap. 5. Connect to the condensate return lines. 6. For steam solenoid valve wiring connections, refer to Wiring Diagram supplied with tumble dryer. 70458301ENR6 © Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT...
  • Page 72 3/4 in. NPT 134 (60.8) 035 Series 80-100 (5.3-6.9) 3/4 in. NPT 166 (75.3) T30 Series 80-100 (5.3-6.9) 3/4 in. NPT 110 (49.9) * Based on100 psi. Table 18 70458301ENR6 © Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT...
  • Page 73: Single Drop Timer

    (dipswitches 1, 2 and 3 in ON position) and 1 minute of minimum cool down time for a total time of 9 minutes for a coin pulse. For dipswitch 70458301ENR6 © Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT...
  • Page 74: Dipswitch Settings

    Single Drop Timer Dipswitch Settings Heat Switch Number Heat Time Per Coin Pulse (in minutes) 8 (factory default) Table 20 (continued) 70458301ENR6 © Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT...
  • Page 75 Per Cycle Switch Number Switch Number (in minutes) (in minutes) 1 (factory 1 (factory default) default) Total Cycle Time = Heat Time + Cool Down Time Table 19 70458301ENR6 © Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT...
  • Page 76: Operating Instructions

    IMPORTANT: This appliance shall not be used to Figure 28 dry off solvents or dry cleaning fluids. T30 AND T45 SERIES TMB2264N Emergency Stop Button Figure 29 70458301ENR6 © Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT...
  • Page 77: Operating Instructions

    15.9 20.5 (per cylinder) 24.9 DO NOT OVERLOAD. NOTE: Overloading causes slow drying and wrinkling. Close loading door. Tumble dryer will not operate with the door open. 70458301ENR6 © Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT...
  • Page 78: Control Instructions

    Anti-wrinkle feature will tumble the load without heat for 30 seconds every 2 minutes for 1 hour OR TMB2145N until the loading door is opened. TMB2145N Figure 33 70458301ENR6 © Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT...
  • Page 79 Allow up to 20 seconds for this condition to clear.  AF (Solid) Cycle Check if airflow switch opens at end of cycle.  Replace airflow switch if inoperative. 70458301ENR6 © Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT...
  • Page 80: Electronic Opl Micro Control

    The intermittent tumbling will continue for one hour or until the door is opened. TMB806N Figure 36 70458301ENR6 © Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT...
  • Page 81: Single Drop Control

    USE LED is off. The control remains in this mode until the door is opened or additional vend has been Error Codes section. satisfied. 4. When the cycle is complete, open door and remove the laundry. 70458301ENR6 © Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT...
  • Page 82 Figure 42 Error Codes Display Definition Corrective Action  Airflow switch opened/closed 5 or more Check airflow switch. Replace if inoperative. AF (flashing) times in a running cycle. 70458301ENR6 © Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT...
  • Page 83: Mdc Coin And Card Control

    W779 Figure 43 2. Insert the coin(s) in the coin slot, or the card into the opening. TMB1963N TMB1492N TMB1963N Figure 44 70458301ENR6 © Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT...
  • Page 84: Quantum Control

    3. Press START pad to start tumble dryer. without heat, up to 18 hours or until door is opened. 70458301ENR6 © Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT...
  • Page 85: Galaxy 600 Control

    Starting 20 minutes after a cycle ends, the cylinder will tumble for two minutes every hour without heat, up to 18 hours or until door is opened. 70458301ENR6 © Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT...
  • Page 86: Led Opl Control

    18 hours or until the door is opened. START ( ) pad must be pressed. 3. When the cycle is complete, open door and remove laundry. 70458301ENR6 © Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT...
  • Page 87: Unilinc Control

    18 hours or until the door is opened. START pad must be pressed. 3. When the cycle is complete, open door and remove laundry. 70458301ENR6 © Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT...
  • Page 88: Dx4 Coin Control

    5. When the cycle is complete, open door and immediately in case of power failure. remove the laundry. W779 WARNING To prevent the risk of fire, remove laundry immediately in case of power failure. W779 70458301ENR6 © Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT...
  • Page 89: Diagnostic Microprocessor Control

    STOP again to cancel the current cycle.  RPM display – when equipped with rotational sensor only  Monitors the lint door switch operation  Monitors the thermistor for operation 70458301ENR6 © Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT...
  • Page 90: Dmp Opl Models

    COOLING LED. Illuminated when in the cooling cycle, or when the display is currently showing the time for the cooling cycle. TEMPERATURE LED. Illuminated when the display is showing the temperature setting. Figure 52 70458301ENR6 © Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT...
  • Page 91 5 seconds when the drying cycle is completed. “ON” indicates that the buzzer will sound continuously until the STOP button is pressed or the loading door is opened. 70458301ENR6 © Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT...
  • Page 92: Dmp Coin

    COOLING LED. Illuminated when in the cooling cycle or when the display is currently showing the time for the cooling cycle. START. Starts or resumes the current program or cycle Temperature Select. This button toggles through the three temperature selections. Figure 53 70458301ENR6 © Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT...
  • Page 93 COOLING time, HIGH temperature setpoint, the display to “PAy”. MEDIUM temperature setpoint, LOW temperature setpoint. 2. An LED will be on to indicate which parameter is flashing on the display. 70458301ENR6 © Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT...
  • Page 94 Reversing Timer Board. and temperature. 13. Toggle between reversing REV (illuminated) or nonreversing REV (not illuminated). (Only for tumble dryers with the reversing option.) 70458301ENR6 © Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT...
  • Page 95 5 seconds every with the rotation sensor.) 2 minutes for a total of 20 minutes, until some function of the tumble dryer is activated/deactivated by the user. 70458301ENR6 © Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT...
  • Page 96: Ignition Control Operation And Troubleshooting For Models Starting 3/11/13

    NOTE: The LED will flash on for 1/4 second, then switch. off for 1/4 second during a fault condition. The pause between fault codes is 3 seconds. 70458301ENR6 © Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT...
  • Page 97: Proper Electrode Location

    1.0 VDC, so a reading of 2.6 VDC would equate to 2.6 micro-amps. TMB 2317K A good burner ground that matches the control ground Figure 54 is critical for reliable flame sensing. 70458301ENR6 © Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT...
  • Page 98: Ignition Control Operation For Non-Ce Models Through 3/10/13

    When this occurs, the control must complete the same prepurge and ignition sequence specified above. 70458301ENR6 © Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT...
  • Page 99: Ignition Control Operation For Ce Models Through 3/10/13

    Lockout Mode with the Diagnostic LED displaying Error Code 2. The ignition control will remain in Run Mode until 24VAC is removed from terminals TH and GND on the control. 70458301ENR6 © Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT...
  • Page 100 Reset Switch is Shorted Slow Red and Green Flashes Low Voltage Detection Fast Red and Orange Flashes Ignition Control is in Reset Delay TMB2176N Diagnostic (DGN) LED Figure 55 70458301ENR6 © Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT...
  • Page 101: Adjustments

    This will assure proper alignment of the airflow switch arm in the channel of the airflow switch bracket and prevent binding of the arm. TMB2105N Switch Actuator Figure 56 70458301ENR6 © Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT...
  • Page 102: Door Strike

    To adjust, open door, loosen acorn nut, and turn door strike screw in or out as required. Retighten acorn nut. TMB997 TMB997N Door Strike Screw Acorn Nut Figure 57 70458301ENR6 © Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT...
  • Page 103: Maintenance

    Rinse with clean water. DO NOT use products that contain alcohol TMB2116N on the control panel. TMB2116N Blower Housing Thermistor Cabinet Thermostat Guard Figure 59 70458301ENR6 © Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT...
  • Page 104: Monthly

     Turn off gas supply external to machine.  Turn off manual gas shut-off valve on machine.  Turn off steam supply external to machine.  Remove all electric, gas and steam connections. 70458301ENR6 © Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT...
  • Page 105: Fire Suppression System Maintenance Test

    MIX1N purchased. Figure 60 70458301ENR6 © Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT...

This manual is also suitable for:

Chd25g2-ct025lChd25g2-ca025nChd25g2-ct025nCk025nChd25g2-cu025nDr25g2-ba025l ... Show all

Table of Contents