ALLIANCE AE9133 Service Manual page 61

Ae/ag/ne/ng series home laundry dryers
Table of Contents

Advertisement

Section 7 Gas Burner Conversion Procedures
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the dryer(s) before servicing.
• Close gas shut-off valve to gas dryer(s) before servicing.
• Never start the dryer(s) with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the dryer is properly grounded.
APPLY NO. 60515
CONVERSION
PLATE
HERE
Figure 43
(1) Loosen air shutter lockscrew. Refer to
Figure 44.
(2) Turn air shutter to the right or left as
necessary to obtain proper flame intensity.
Refer to Figure 44.
(3) After air shutter is adjusted for proper
flame, tighten air shutter lockscrew firmly.
p. Be sure and observe at least two complete
ignition and burn cycles before reinstalling
access door.
q. Reinstall the access door and screw.
WARNING
For personal safety, access door must be in
place during normal operation.
60
NAMEPLATE
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
WARNING
AIR SHUTTER
LOCKSCREW
GAS VALVE
PRESSURE TAP
MANOMETER
DRY965S
AIR
SHUTTER
Figure 44
W001R1
10 ± 1.5
INCHES
60549

Advertisement

Table of Contents
loading