Connect Electrical Plug (Electric Dryer Only); Grounding Information - ALLIANCE Speed Queen DR7003WG Installation Instructions Manual

Table of Contents

Advertisement

Installation
1
5
4
1. New Stainless Steel Flexible Connector – (Use design
CSA certified connector) Use only if allowed by local co-
des
2. 1/8 in. NPT Pipe Plug
3. Equipment Shut-Off Valve
4. Black Iron Pipe:
Shorter than 20 ft. [6.1 m] – Use 3/8 in. [9.5 mm] pipe.
Longer than 20 ft. [6.1 m] – Use 1/2 in. [12.7 mm] pipe.
5. 3/8 in. NPT Gas Connection
4. Tighten all connections securely but don't overtighten to avoid
breaking or bending the gas valve bracket. Turn on gas and
check all pipe connections (internal & external) for gas leaks
with a non-corrosive leak detection fluid.
NOTE: The dryer and its appliance main gas valve must
be disconnected from the gas supply piping system
during any pressure testing of that system at test pres-
sures in excess of 1/2 psi [3.45 kPa] . Refer to Check
Heat Source.
NOTE: DO NOT connect the dryer to L.P. Gas Service
without converting the gas valve. Install L.P. Gas Con-
version Kit 649P3, available at extra cost.
L.P. (Liquefied Petroleum) Gas, 2500 Btu/ft.
service must be supplied at 10 ± 1.5 inch water column pressure.
For proper operation at altitudes above 3000 feet [915 m] the L.P.
gas valve spud orifice size must be reduced to ensure complete
combustion. Refer to Table 4 .
©
Copyright, Alliance Laundry Systems LLC -
DO NOT COPY or TRANSMIT
2
3
D233I_SVG
Figure 7
3
[93.1 MJ/m
Altitude
feet [m]
3000 [915]
8000 [2440]
Connect Electrical Plug (Electric Dryer
Only)
Dryer requires 120/240 Volt or 120/208 Volt, 60 Hertz, 3 or 4
wire electrical supply. Refer to serial plate for specific electrical
requirements.
IMPORTANT: Use only a new U.L. listed No. 10 (copper
wire only) three or four conductor power supply cord
kit rated 240 Volts (minimum) 30 Amperes and labeled
as suitable for use in a clothes dryer.
NOTE: The wiring diagram is located in the control
hood.
To reduce the risk of fire, electric shock, serious in-
jury or death, all wiring and grounding MUST con-
form with the latest edition of the National Electrical
Code, ANSI/NFPA 70, or the Canadian Electrical
Code, CSA C22.1, and such local regulations as
might apply. It is the customer's responsibility to
have the wiring and fuses installed by a qualified
electrician to make sure adequate electrical power is
available to the dryer.

Grounding Information

This appliance must be grounded. In the event of malfunction or
breakdown, grounding will reduce the risk of electric shock by
3
] ,
providing a path of least resistance for electric current. The cord-
kit must be equipped with a cord having an equipment-grounding
conducator and a grounding plug. The plug must be plugged into
an appropriate outlet that is properly installed and grounded in
accordance with all local codes and ordinances.
16
L.P. Altitude Adjustments
Orifice Size
No.
inches [mm]
55
0.0520 [1.32]
56
0.0465 [1.18]
Table 4
WARNING
Part No. D518518ENR1
Part No.
58755
D503786
W521