79. SYMPTOM: FLASHING DISPLAY

NOTE: Refer to Figure 59 to aid in this Troubleshooting section.
Was door open or was the STOP
pad pressed after dryer was
running?
Unplug power cord and check
Unplug power cord and check
outlet for proper polarity and
outlet for proper polarity and
grounding. Refer to .
grounding. Refer to Figure 57.
Polarity and grounding okay?
Remove control hood and
check for loose or incorrect wiring
to terminals "P2" and "P3" on the
control.
Place test meter between
terminals "P2" (door) and "P3"
(neutral) on control.
Approximately 120 Volts between
"P2" and "P3" when door is closed
and "0" Volts when door is open?
Recheck from beginning.
If problem persists, replace
control.
60549
Section 8 Service Procedures Unique to Electronic Control Model Dryers
NO
NO
YES
YES
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
WARNING
Normal operation. Refer to
YES
Operating Instructions.
NO
Contact electrician.
NO
Check door switch and wiring from
door switch to the control.