ALLIANCE AE9133 Service Manual page 74

Ae/ag/ne/ng series home laundry dryers
Table of Contents

Advertisement

To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the dryer(s) before servicing.
• Close gas shut-off valve to gas dryer(s) before servicing.
• Never start the dryer(s) with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the dryer is properly grounded.
c. Four-Wire Power Cord
IMPORTANT: Use only a U.L. listed No. 10 A.W.G.
(copper wire only) four conductor power supply
cord kit rated 240 Volts (minimum) 30 Amperes
and labeled as suitable for use in a clothes dryer.
WARNING
This type of installation MUST be made on
mobile home dryers.
TYPICAL
FOUR-WIRE
STRAIN
RECEPTACLE
RELIEF
Figure 55
NOTE: The power cord is not supplied with the
dryer when the dryer is shipped from the factory,
therefore, disregard Steps 2 and 3 below when
connecting a four-wire power cord to a NEW dryer.
If the dryer has a three-wire cord attached, then
complete Steps 1 through 11.
WARNING
To reduce the risk of electric shock,
disconnect the electrical service to the
dryer before proceeding.
60549
Section 8 Service Procedures Unique to Electronic Control Model Dryers
POWER CORD
(Four-Wire)
STRAIN
RELIEF
NUT
DRY1065S
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
WARNING
(1) Remove the screw holding the access plate
to the rear of dryer cabinet.
(2) Through Serial No. S6271975XG–
Remove three nuts and cupped washers
holding the three wires to terminal block
terminals. Save the nuts and washers.
Starting Serial No. S6271976XG–
Remove three screws holding the three
wires to terminal block terminals. Save
these screws.
(3) Loosen the strain relief screw and pull the
cord or wires out through the rear of the
dryer.
(4) Remove the terminal bracket ground screw
holding the green ground wire to the
terminal block mounting bracket. Save the
screw.
NOTE: ON NEW DRYERS – This is the green
ground wire that goes from the neutral (center)
terminal on the terminal block to the mounting
bracket.
Install Four-Wire Power Cord
(5) Route the end of the four-wire power cord
through the strain relief. DO NOT tighten
the strain relief screws at this time.
(6) Insert the end of the power cord and strain
relief through the hole in the rear of dryer
cabinet. Refer to Figure 56. Install the
strain relief nut from the inside of the
cabinet and tighten firmly.
(7) Attach the green ground wire (from the
four-wire power cord) to the terminal block
mounting bracket using the hex head screw
removed in Step 4. Tighten the screw
firmly.
(8) Install matching colored wires (from four-
wire power cord) to the matching colored
wires from wire harness on terminal block
terminals (i.e., red to red, white to white
and black to black)
W135
W001R1
73

Advertisement

Table of Contents
loading

Table of Contents