Section 7 Gas Burner Conversion Procedures
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the dryer(s) before servicing.
• Close gas shut-off valve to gas dryer(s) before servicing.
• Never start the dryer(s) with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the dryer is properly grounded.
(4) Stop dryer and remove "U " tube and
reinstall the pressure tap pipe plug. Refer to
Figure 47 .
MANOMETER
AIR SHUTTER
LOCKSCREW
GAS VALVE
PRESSURE TAP
Figure 50
m. Check the gas line connection for gas leaks with
a soapy solution.
DANGER
To reduce the risk of an explosion or fire,
do not use an open flame to check for gas
leaks!
n. Make sure the dryer conversion has been
completed. Recheck the following:
(1) Installed correct orifice spud (#44), see
step "e".
(2) Installed the vent screw, see step "g".
(3) Gas valve pressure must be 3.5 ± .2 inches
(8.89 ± .508 cm), see step "l".
64
3.5 ± .2
INCHES
DRY965S
AIR
SHUTTER
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
WARNING
(4) Installed four stickers, see steps "h", "i",
and "j".
o. Start dryer and observe burner flame. Adjust air
shutter to obtain a soft, uniform flame. (A lazy,
orange tipped flame indicates lack of air. A
harsh, roaring, very blue flame indicates too
much air.) Adjust air shutter to obtain a soft
uniform blue flame as follows:
(1) Loosen air shutter lockscrew. Refer to
Figure 50.
(2) Turn air shutter to the right or left as
necessary to obtain proper flame intensity.
Refer to Figure 50.
(3) After air shutter is adjusted for proper
flame, tighten air shutter lockscrew firmly.
p. Be sure and observe at least two complete
ignition and burn cycles before reinstalling
access door.
q. Reinstall the access door and screw.
For personal safety, access door must be in
place during normal operation.
WARNING
W001R1