ALLIANCE BA120E Installation Manual

Tumble dryers
Table of Contents

Advertisement

Models with 0 or 3 in 13th Position of Model Number
Original Instructions
Keep These Instructions for Future Reference.
CAUTION: Read the instructions before using the machine.
(If this machine changes ownership, this manual must accompany machine.)
120 Pound (55 Kilogram) Capacity
170 Pound (77 Kilogram) Capacity
200 Pound (90 Kilogram) Capacity
Refer to Page 8 for Model Identification
www.alliancelaundry.com
Tumble Dryers
TMB1282C_SVG
Part No. 70532501ENR7
December 2018

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the BA120E and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for ALLIANCE BA120E

  • Page 1 Tumble Dryers 120 Pound (55 Kilogram) Capacity 170 Pound (77 Kilogram) Capacity 200 Pound (90 Kilogram) Capacity Models with 0 or 3 in 13th Position of Model Number Refer to Page 8 for Model Identification TMB1282C_SVG Original Instructions Keep These Instructions for Future Reference. CAUTION: Read the instructions before using the machine.
  • Page 3 National Instal- ing. lation Regulations. W925 IMPORTANT: The tumble dryer is not to be used if in- dustrial chemicals have been used for cleaning. © Copyright, Alliance Laundry Systems LLC - Part No. 70532501ENR7 DO NOT COPY or TRANSMIT...
  • Page 4 DO NOT let children play on or in the dryer. W931 To reduce the risk of serious injury: Avoid contact with hot surfaces. In Australia and New Zealand: W927 © Copyright, Alliance Laundry Systems LLC - Part No. 70532501ENR7 DO NOT COPY or TRANSMIT...
  • Page 5 A “T-Handle” type gas shut-off valve must be installed in the gas supply line to this appliance. • This appliance must not be installed in a bedroom or bath- room. © Copyright, Alliance Laundry Systems LLC - Part No. 70532501ENR7 DO NOT COPY or TRANSMIT...
  • Page 6: Table Of Contents

    Manifold Venting..................33 © Copyright 2018, Alliance Laundry Systems LLC All rights reserved. No part of the contents of this book may be reproduced or transmitted in any form or by any means without the expressed written consent of the publisher.
  • Page 7 Belt Drive....................63 Upper Belt Tension..................64 Lower Belt Tension................... 64 Before You Call for Service..............65 Removing Tumble Dryer from Service..........66 Disposal of Unit..................67 © Copyright, Alliance Laundry Systems LLC - Part No. 70532501ENR7 DO NOT COPY or TRANSMIT...
  • Page 8 China Restriction of hazardous substances (RoHS)....... 68 © Copyright, Alliance Laundry Systems LLC - Part No. 70532501ENR7 DO NOT COPY or TRANSMIT...
  • Page 9: Introduction

    BU120L HA120E HT120S NK120E PJ120E SG120S UA120N UU120L BU120N HA120L HU120E NK120L PJ120L SH120E UA120S UU120N BU120S HA120N HU120L NK120N PJ120N SH120L UG120E UU120S GA120E © Copyright, Alliance Laundry Systems LLC - Part No. 70532501ENR7 DO NOT COPY or TRANSMIT...
  • Page 10 HT170S NK170L PJ170L SG170S UA170N UU170L BU170N HA170L HU170L NK170N PJ170N SH170L UA170S UU170N BU170S HA170N HU170N NR170S PJ170S SH170N UG170L UU170S GA170L HA170S HU170S © Copyright, Alliance Laundry Systems LLC - Part No. 70532501ENR7 DO NOT COPY or TRANSMIT...
  • Page 11 HU200S Heater Digit (Position 6) C - Steam (CRN) E - Electric L - Liquid Petroleum (L.P.) Gas N - Natural Gas S - Steam © Copyright, Alliance Laundry Systems LLC - Part No. 70532501ENR7 DO NOT COPY or TRANSMIT...
  • Page 12: Contact Information

    The first two digits indicate the year. The third and fourth digits indicate the month. For example, a unit with serial number 1505000001 was manufactured in May 2015. © Copyright, Alliance Laundry Systems LLC - Part No. 70532501ENR7 DO NOT COPY or TRANSMIT...
  • Page 13: Safety Information

    • Cleaning and user maintenance shall not be made by children • Read all instructions before using the tumble dryer. without supervision. © Copyright, Alliance Laundry Systems LLC - Part No. 70532501ENR7 DO NOT COPY or TRANSMIT...
  • Page 14 ALWAYS disconnect and lockout the electrical power to the tumble dryer before servicing. Disconnect power by shut- ting off appropriate breaker or fuse. © Copyright, Alliance Laundry Systems LLC - Part No. 70532501ENR7 DO NOT COPY or TRANSMIT...
  • Page 15: Specifications And Dimensions

    1.5 [1.1] Fan Motor: HP [kW] 1.5 [1.1] 1.5 [1.1] 1.5 [1.1] Air Outlet Diameter: Inches [mm] 10.0 [254] 12.0 [305] 12.0 [305] Table continues... © Copyright, Alliance Laundry Systems LLC - Part No. 70532501ENR7 DO NOT COPY or TRANSMIT...
  • Page 16 Heating Element Rating: Kilowatts Not Applicable Not Applicable (kW) NOTE: All IEC machines are shipped with an adapter to convert the gas connection threads to BSPT (from NPT). © Copyright, Alliance Laundry Systems LLC - Part No. 70532501ENR7 DO NOT COPY or TRANSMIT...
  • Page 17: Cabinet Dimensions And Exhaust Outlet Locations

    Refer to Position and Level the Tumble Dryer to temporarily re- duce the heights of these models. Rear Exhaust Dimensions, in. [mm] Models Diameter Table continues... © Copyright, Alliance Laundry Systems LLC - Part No. 70532501ENR7 DO NOT COPY or TRANSMIT...
  • Page 18 Specifications and Dimensions Rear Exhaust Dimensions, in. [mm] 10.0 [250] 7.6 [195] 7.6 [195] 12.0 [305] 8.8 [225] 11.0 [280] 12.0 [305] 8.8 [225] 11.0 [280] © Copyright, Alliance Laundry Systems LLC - Part No. 70532501ENR7 DO NOT COPY or TRANSMIT...
  • Page 19: Electric And Gas Connection Locations For Gas Models

    12.9 [330] 70.2 [1785] 1 NPT 8.0 [205] 63.7 [1620] 14.6 [370] 77.4 [1965] 1 NPT 8.0 [205] 63.7 [1620] 14.6 [370] 77.4 [1965] 1 NPT © Copyright, Alliance Laundry Systems LLC - Part No. 70532501ENR7 DO NOT COPY or TRANSMIT...
  • Page 20: Electric And Steam Connection Locations For Steam Models

    Diameter 3/4 NPT 34.6 [880] 13.1 [335] 68.5 [1740] 1 NPT 44.0 [1120] 9.0 [230] 72.0 [1830] 1 NPT 44.0 [1120] 9.0 [230] 72.0 [1830] © Copyright, Alliance Laundry Systems LLC - Part No. 70532501ENR7 DO NOT COPY or TRANSMIT...
  • Page 21 Specifications and Dimensions Electrical Connection, in. [mm] Models 3.9 [100] 60.9 [1545] 8.0 [205] 63.7 [1620] 8.0 [205] 63.7 [1620] © Copyright, Alliance Laundry Systems LLC - Part No. 70532501ENR7 DO NOT COPY or TRANSMIT...
  • Page 22: Electric Connection Location For Electric Models

    Specifications and Dimensions Electric Connection Location for Electric Models TMB2578N_SVG 1. Electrical Connection 2.5 in. [64 mm] Diameter Connection Dimensions, in. [mm] Models 36.4 [925] 85.6 [2175] © Copyright, Alliance Laundry Systems LLC - Part No. 70532501ENR7 DO NOT COPY or TRANSMIT...
  • Page 23: Installation

    © Copyright, Alliance Laundry Systems LLC - Part No. 70532501ENR7 DO NOT COPY or TRANSMIT...
  • Page 24: Remove Shipping Materials

    IMPORTANT: Remove the yellow shipping wire tie se- clockwise by using the lifter. The insert will drop into the lint curing the airflow switch. © Copyright, Alliance Laundry Systems LLC - Part No. 70532501ENR7 DO NOT COPY or TRANSMIT...
  • Page 25: Position And Level The Tumble Dryer

    IMPORTANT: Main supplies of electricity and water to the tumble dryer should remain on at all times for the fire suppression system to work. © Copyright, Alliance Laundry Systems LLC - Part No. 70532501ENR7 DO NOT COPY or TRANSMIT...
  • Page 26: Water Connections

    To connect the two hoses (supplied with tumble dryer), insert rubber washers (from literature pack) in water inlet hose cou- plings. Refer to Figure 4 . © Copyright, Alliance Laundry Systems LLC - Part No. 70532501ENR7 DO NOT COPY or TRANSMIT...
  • Page 27: Electrical Requirements

    Order hoses as follows: Part No. 20617 Inlet hose 8.0 feet [2.4 m] Part No. 20618 Inlet hose 10 feet [3.0 m] © Copyright, Alliance Laundry Systems LLC - Part No. 70532501ENR7 DO NOT COPY or TRANSMIT...
  • Page 28: Before Placing Tumble Dryer Into Service

    Adjust the air inlet shutter as required. Refer to Adjustments section. W407R1 10. Clean cylinder by running a load of wet rags on one maxi- mum heat cycle. © Copyright, Alliance Laundry Systems LLC - Part No. 70532501ENR7 DO NOT COPY or TRANSMIT...
  • Page 29: Required For Iec Models Only

    On front panel near emergency stop button (fire suppres- sion system equipped models only) • On fire suppression control box (fire suppression system equipped models only) © Copyright, Alliance Laundry Systems LLC - Part No. 70532501ENR7 DO NOT COPY or TRANSMIT...
  • Page 30: Exhaust Requirements

    For maximum efficiency and minimum lint accumulation, tumble dryer air must be exhausted to the outdoors by the shortest possi- ble route. © Copyright, Alliance Laundry Systems LLC - Part No. 70532501ENR7 DO NOT COPY or TRANSMIT...
  • Page 31 It is better to have the water heater in a separate room with a separate air inlet. © Copyright, Alliance Laundry Systems LLC - Part No. 70532501ENR7 DO NOT COPY or TRANSMIT...
  • Page 32: Individual Venting

    Specifi- cations and Dimensions Table or on the installation sticker on the rear of the tumble dryer. Table 1  continues... © Copyright, Alliance Laundry Systems LLC - Part No. 70532501ENR7 DO NOT COPY or TRANSMIT...
  • Page 33: Manifold Venting

    Figure 8 exceeds 14 feet [4.3 m] and two 90° elbows. The diameter of a © Copyright, Alliance Laundry Systems LLC - Part No. 70532501ENR7 DO NOT COPY or TRANSMIT...
  • Page 34 NOTE: Table 2 represents tumble dryers with the same NOTE: Duct clean-out recommended every 6 feet [0.18 vent size. If multiple vent sizes are used, consult a lo- cal HVAC specialist. © Copyright, Alliance Laundry Systems LLC - Part No. 70532501ENR7 DO NOT COPY or TRANSMIT...
  • Page 35 1. Outlet duct diameter = combined largest duct diameter of both sides 2. 45° typical Figure 10 Refer to Table 2 for measurements for each manifold. © Copyright, Alliance Laundry Systems LLC - Part No. 70532501ENR7 DO NOT COPY or TRANSMIT...
  • Page 36: Gas Requirements

    Use the individual man- ual shut-off valve from the gas supply piping system to protect the gas valve. © Copyright, Alliance Laundry Systems LLC - Part No. 70532501ENR7 DO NOT COPY or TRANSMIT...
  • Page 37 Maximum 13 in. w.c. 3.23 kPa Refer to Table Recommend- 11 in. w.c. 2.74 kPa Minimum 10 in. w.c. 2.49 kPa © Copyright, Alliance Laundry Systems LLC - Part No. 70532501ENR7 DO NOT COPY or TRANSMIT...
  • Page 38 3B/P 42.5 57.5 27.5 2E(r) 2E(r)3+ 2E(r) 12.0 3+ (30/37) Bu- 30 (28-30) tane 3+ (30/37) Propane 12.0 2L3B/P 3B/P 30 (28-30) Table 3  continues... © Copyright, Alliance Laundry Systems LLC - Part No. 70532501ENR7 DO NOT COPY or TRANSMIT...
  • Page 39 4. 3 in. [76 mm] Minimum Gas Pipe tion. If in doubt, the installer shall contact the supplier. 5. Gas Pipe Cap 6. Sediment Trap Figure 11 © Copyright, Alliance Laundry Systems LLC - Part No. 70532501ENR7 DO NOT COPY or TRANSMIT...
  • Page 40: How To Change Burner Orifice Size

    How to Adjust Gas Valve Governor/Regulator 1. Check gas burner orifice (manifold) pressure as follows. Re- fer to Figure 13 . 2. Remove screw plug from pressure tap. © Copyright, Alliance Laundry Systems LLC - Part No. 70532501ENR7 DO NOT COPY or TRANSMIT...
  • Page 41: Installing Ce Gas Tumble Dryer

    Table 3 . start the cycle. Repeat these steps until burner ignites. Use pipe compound, resistant to actions of L.P. gas, on all pipe threads. © Copyright, Alliance Laundry Systems LLC - Part No. 70532501ENR7 DO NOT COPY or TRANSMIT...
  • Page 42: Gas Supply Pipe Sizing And Looping

    Total Btu/hr. = The sum of the Btu/hr. of all 120 series tumble dryers being fed by the main gas supply pipe. = 9 x 270,000 [285, 79] © Copyright, Alliance Laundry Systems LLC - Part No. 70532501ENR7 DO NOT COPY or TRANSMIT...
  • Page 43: Low Pressure Gas Pipe Sizes

    2-1/2 2-1/2 2-1/2 1,300,000 2-1/2 2-1/2 2-1/2 2-1/2 1,400,000 2-1/2 2-1/2 2-1/2 2-1/2 1,500,000 2-1/2 2-1/2 2-1/2 2-1/2 1,600,000 2-1/2 2-1/2 2-1/2 Table 4  continues... © Copyright, Alliance Laundry Systems LLC - Part No. 70532501ENR7 DO NOT COPY or TRANSMIT...
  • Page 44 3-1/2 For L.P. Gas, correct the total Btu/hr by multiplying it by 0.6. The answer is the equivalent Btu on the above chart. Table 4 © Copyright, Alliance Laundry Systems LLC - Part No. 70532501ENR7 DO NOT COPY or TRANSMIT...
  • Page 45: High Pressure Gas Pipe Sizes

    140,000 160,000 180,000 200,000 300,000 400,000 500,000 600,000 700,000 800,000 900,000 1,000,000 1,100,000 1,200,000 1,300,000 1-1/4 1,400,000 1-1/2 1,500,000 1-1/4 1,600,000 1-1/4 Table 5  continues... © Copyright, Alliance Laundry Systems LLC - Part No. 70532501ENR7 DO NOT COPY or TRANSMIT...
  • Page 46 1-1/2 For L.P. Gas, correct the total Btu/hr by multiplying it by 0.6. The answer is the equivalent Btu on the above chart. Table 5 © Copyright, Alliance Laundry Systems LLC - Part No. 70532501ENR7 DO NOT COPY or TRANSMIT...
  • Page 47: High Altitude Orifice Sizing

    Heat input derate of 4% per 1000 feet [305 meters] of alti- tude above sea level. Refer to Table 6 . © Copyright, Alliance Laundry Systems LLC - Part No. 70532501ENR7 DO NOT COPY or TRANSMIT...
  • Page 48 0.1040 M401024 [610-1,220] [2.64] 4,001-6,000 0.1015 M411376 [ 1,221-1,830] [2.58] 6,001-8,000 0.0980 M406361 [ 1,831-2,440] [2.49] 8,001-10,000 0.0935 M403017 [ 2,441-3,050] [2.37] Table 6  continues... © Copyright, Alliance Laundry Systems LLC - Part No. 70532501ENR7 DO NOT COPY or TRANSMIT...
  • Page 49 0.1065 M411375 [610-1,220] [2.71] 4,001-6,000 0.1040 M401024 [ 1,221-1,830] [2.64] 6,001-8,000 0.0995 M401007 [ 1,831-2,440] [2.53] 8,001-10,000 0.0960 M401015 [ 2,441-3,050] [2.44] Table 6  continues... © Copyright, Alliance Laundry Systems LLC - Part No. 70532501ENR7 DO NOT COPY or TRANSMIT...
  • Page 50 2,001-4,000 0.1100 M402487 [610-1,220] [2.79] 4,001-6,000 0.1065 M411375 [ 1,221-1,830] [2.71] 6,001-8,000 0.1040 M401024 [ 1,831-2,440] [2.64] 8,001-10,000 0.0995 M401007 [ 2,441-3,050] [2.53] Table 6 © Copyright, Alliance Laundry Systems LLC - Part No. 70532501ENR7 DO NOT COPY or TRANSMIT...
  • Page 51: Electrical Requirements

    W943 • A dedicated ground conduit (wire) must be connected be- tween the electrical service box ground bar and tumble dryer ground screw. © Copyright, Alliance Laundry Systems LLC - Part No. 70532501ENR7 DO NOT COPY or TRANSMIT...
  • Page 52: For On Premises Laundry (Opl) Models Only

    Ground and Terminal Block Locations Gas and Steam TMB2450N_SVG 1. Ground 2. Power Distribution Block Electric (120 only) TMB2473N_SVG 1. Ground 2. Power Distribution Block © Copyright, Alliance Laundry Systems LLC - Part No. 70532501ENR7 DO NOT COPY or TRANSMIT...
  • Page 53: Electrical Specifications

    L1, L2, L3 14 [2.5] and ground 440-480 50-60 L1, L2, L3 14 [2.5] and ground 380-415 50-60 L1, L2, L3 14 [2.5] and ground Table 7 © Copyright, Alliance Laundry Systems LLC - Part No. 70532501ENR7 DO NOT COPY or TRANSMIT...
  • Page 54 Block Con- Amps ed Circuit AWG [mm2] nections Re- Breaker Rat- quired ing Amps 200-240 50-60 L1, L2, L3 14 [2.5] and ground Table 10  continues... © Copyright, Alliance Laundry Systems LLC - Part No. 70532501ENR7 DO NOT COPY or TRANSMIT...
  • Page 55 Electrical Requirements 440-480 50-60 L1, L2, L3 14 [2.5] and ground 380-415 50-60 L1, L2, L3 14 [2.5] and ground Table 10 © Copyright, Alliance Laundry Systems LLC - Part No. 70532501ENR7 DO NOT COPY or TRANSMIT...
  • Page 56: Steam Requirements

    If pockets or im- ers in the lint compartment. proper drainage cannot be eliminated, install a bypass trap to © Copyright, Alliance Laundry Systems LLC - Part No. 70532501ENR7 DO NOT COPY or TRANSMIT...
  • Page 57 8. 18 in. [460 mm] Drop Recommended (not above outlet) 9. Solenoid Valve (Supplied with machine) 10. Steam Bonnet 11. Flexible Line 12. Union 13. Trap with Built-In Strainer Figure 16 © Copyright, Alliance Laundry Systems LLC - Part No. 70532501ENR7 DO NOT COPY or TRANSMIT...
  • Page 58 Steam Trap Size* Pounds Con- densate/Hour [Kilograms Con- Steam Pressure PSI [bar] Minimum Supply Pipe Diameter densate/Hour] 80-100 [5.3-6.9] 1 NPT 345 [156] *Based on 6.9 bar. Table 11 © Copyright, Alliance Laundry Systems LLC - Part No. 70532501ENR7 DO NOT COPY or TRANSMIT...
  • Page 59 6. Drop 18 in. [460 mm] Recommended (not above outlet) 7. Steam Bonnet 8. Solenoid Valve (Supplied with machine) 9. Union 10. Trap with Built-In Strainer 11. Return 12. Supply Figure 17 © Copyright, Alliance Laundry Systems LLC - Part No. 70532501ENR7 DO NOT COPY or TRANSMIT...
  • Page 60: Piping Recommendations

    18 inches [460 mm] recommended below the steam coil outlet connections. 4. Install a shut-off valve to each steam trap. 5. Connect to the condensate return lines. © Copyright, Alliance Laundry Systems LLC - Part No. 70532501ENR7 DO NOT COPY or TRANSMIT...
  • Page 61: Adjustments

    Adjust air shutter as fol- lows: Refer to Figure 18 . 1. Remove the burner inspection hole plate. © Copyright, Alliance Laundry Systems LLC - Part No. 70532501ENR7 DO NOT COPY or TRANSMIT...
  • Page 62: Airflow Switch

    These should be checked and the required corrective action taken. © Copyright, Alliance Laundry Systems LLC - Part No. 70532501ENR7 DO NOT COPY or TRANSMIT...
  • Page 63: Loading Door Strike (200 Series Models)

    The cabinet rear center braces have vertically slotted holes allowing up and down movement of the idler housing for belt adjustment. Refer to Figure 22 . © Copyright, Alliance Laundry Systems LLC - Part No. 70532501ENR7 DO NOT COPY or TRANSMIT...
  • Page 64: Upper Belt Tension

    After Run-in quency Frequency Upper Belt 115 Hz +/-4 Hz 102 Hz +15/-2 Hz Lower Belt 105 Hz +4/-2 Hz 102 Hz +4/-2 Hz Table 13 © Copyright, Alliance Laundry Systems LLC - Part No. 70532501ENR7 DO NOT COPY or TRANSMIT...
  • Page 65: Before You Call For Service

    Tumble dryer is in Cool Down Mode. • • Lint screen clogged. Clean lint screen. • • Exhaust duct to outside is blocked. Clean out. © Copyright, Alliance Laundry Systems LLC - Part No. 70532501ENR7 DO NOT COPY or TRANSMIT...
  • Page 66: Removing Tumble Dryer From Service

    3. Turn off manual gas shut-off valve on machine. 4. Turn off steam supply external to machine. 5. Remove all electric, gas and steam connections. © Copyright, Alliance Laundry Systems LLC - Part No. 70532501ENR7 DO NOT COPY or TRANSMIT...
  • Page 67: Disposal Of Unit

    MIX1N_SVG Figure 23 © Copyright, Alliance Laundry Systems LLC - Part No. 70532501ENR7 DO NOT COPY or TRANSMIT...
  • Page 68 NOTE: The referenced Environmental Protection Use Period Marking was determined according to normal oper- ating use conditions of the product such as temperature and humidity. This product under normal use, durable years of environmental protection is 15 years. © Copyright, Alliance Laundry Systems LLC - Part No. 70532501ENR7 DO NOT COPY or TRANSMIT...

This manual is also suitable for:

Ga120eHa120nHu120lPk120nNk120nSj120e ... Show all

Table of Contents