Symptom: Control Will Not Wake Up (No Led's Light) After Select Pad Is Pressed - ALLIANCE AE9133 Service Manual

Ae/ag/ne/ng series home laundry dryers
Table of Contents

Advertisement

To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the dryer(s) before servicing.
• Close gas shut-off valve to gas dryer(s) before servicing.
• Never start the dryer(s) with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the dryer is properly grounded.
81. SYMPTOM: CONTROL WILL NOT WAKE UP (No LED'S Light) AFTER SELECT PAD IS
PRESSED
Power cord plugged in?
Proper voltage, polarity and
grounding at outlet? Refer to
Figure 57.
Check to see that voltage is being
applied to control.
Approximately 120 Volts between
terminals "P3" (neutral) and
"COM" on heat relay K2?
Unplug power cord and disconnect
wires from terminals "P3" and
"COM". Take resistance reading
through transformer.
*166 Ohms ± 30% between "P3"
and "COM" terminals.
Recheck from beginning. If
problem exists, after checking for
loose, broken or incorrect wiring,
replace control.
*This measurement should be made with a digital Multi-Meter set at 200 Ohm scale for best precision.
60549
Section 8 Service Procedures Unique to Electronic Control Model Dryers
YES
YES
YES
YES
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
WARNING
NO
Plug in.
Go to "Symptom: Blown
NO
Fuse Or Tripped Circuit
Breaker", Paragraph 80.
Check for broken, loose
NO
or incorrect wiring from
outlet to control.
NO
Replace control.
W001R1
83

Advertisement

Table of Contents
loading