050 And 075 Series Electric Models - ALLIANCE CA050L Installation Operation & Maintenance

050 series 075 series 50 pound (22.7 kilogram) capacity 75 pound (34 kilogram) capacity
Hide thumbs Also See for CA050L:
Table of Contents

Advertisement

Electrical Requirements

050 and 075 Series Electric Models

Serial Plate Rating
240V/50Hz/1ph
(050 Series only)
200-208V/60Hz/3ph
200V/50Hz/3ph
230V/50Hz/3ph
240V/50Hz/3ph
240V/60Hz/3ph
380V/50 or 60Hz/3ph
400-415V/50Hz/3ph
440V/60Hz/3ph
480V/60Hz/3ph
50
Terminal Block
Connections Required
L1, Neutral and Ground
L1, L2, L3 and ground
L1, L2, L3 and ground
L1, L2, L3 and ground
L1, L2, L3 and ground
L1, L2, L3 and ground
L1, L2, L3 and ground
L1, L2, L3 and ground
L1, L2, L3 and ground
L1, L2, L3 and ground
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Serial Plate Amps
Nonreversing Reversing
93
95
89
88
84
85
73
75
79
78
79
78
47
48
43
44
41
41
38
38
Table 10
Recommended Circuit
Wire Size
Breaker
Rating
AWG (mm
125A – 1 pole
1 (35)
125A – 3 pole
1 (35)
125A – 3 pole
1 (35)
100A – 3 pole
3 (26.7)
100A – 3 pole
3 (26.7)
100A – 3 pole
3 (26.7)
60A – 3 pole
6 (16)
60A – 3 pole
6 (16)
51A – 3 pole
6 (16)
50A – 3 pole
6 (16)
70457901ENR7
2
)

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ct050nCu050lCa050nCu050nDr50g2-ba050lDr50g2-ba050n ... Show all