Section 7 Gas Burner Conversion Procedures
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the dryer(s) before servicing.
• Close gas shut-off valve to gas dryer(s) before servicing.
• Never start the dryer(s) with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the dryer is properly grounded.

63. INSTALLING THE NO. 402P3 KIT

WARNING
To reduce the risk of electrical shock,
disconnect electrical power to the dryer
before servicing the dryer.
a. Apply thumb pressure to the right side of access
door. Refer to Figure 46. When door opens,
move door to the left to disengage from door
supports.
ACCESS
DOOR
Figure 46
WARNING
To reduce the risk of fire and explosion,
reach in through access door opening and
turn the gas line shut-off valve handle to
the closed position. Refer to Figure 41.
b. Disconnect igniter wires at quick disconnect
blocks. Refer to Figure 47.
62
APPLY
PRESSURE
HERE
SUPPORT
DRY951S
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
WARNING
c. Remove hex head screw holding burner tube
and igniter in place. Refer to Figure 47.
d. Carefully move burner tube toward rear of
dryer, far enough to permit removal of burner
orifice spud from gas valve.
NOTE: Tab on burner tube may have to be
removed from slot in burner housing to obtain
enough clearance.
APPLY NO. 60516
VALVE CONVERTED
STICKER HERE
CLOSED
POSITION
SHUT-OFF
HANDLE
OPEN
POSITION
BLOCK OPEN
PLUG
BLOCK
OPEN
PLUG
VALVE
TOP VIEW OF
GAS VALVE
IGNITER QUICK
DISCONNECT BLOCKS
PRESSURE TAP
PIPE PLUG
Figure 47
W001R1
BURNER
ORIFICE
SPUD
HEX
HEAD
SCREW
BURNER
TUBE
DRY967S
60549