Symptom: Blown Fuse Or Tripped Circuit Breaker - ALLIANCE AE9133 Service Manual

Ae/ag/ne/ng series home laundry dryers
Table of Contents

Advertisement

Section 8 Service Procedures Unique to Electronic Control Model Dryers
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the dryer(s) before servicing.
• Close gas shut-off valve to gas dryer(s) before servicing.
• Never start the dryer(s) with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the dryer is properly grounded.

80. SYMPTOM: BLOWN FUSE OR TRIPPED CIRCUIT BREAKER

YES
Unplug power cord and disconnect
wires from terminals "P3" and
"COM". Take resistance reading
between terminals.
*166 Ohms ± 30% between "P3"
and "COM" terminals.
YES
Check for broken, loose or
incorrect wiring.
Wiring okay?
YES
Recheck from beginning. If
problem persists, replace control.
*This measurement should be made with a digital Multi-Meter set at 200 Ohm scale for best precision.
82
Fuse blown or tripped breaker?
Reset breaker or replace fuse.
Does fuse or breaker blow
immediately upon plugging in
power cord?
NO
Replace
control.
NO
Correct
wiring.
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
WARNING
NO
Does fuse or breaker blow
immediately after motor starts?
NO
Does fuse or breaker blow 15
seconds after motor starts?
YES
Check heater circuit for
shorted, broken, loose or
incorrect wiring.
W001R1
YES
Check motor and
motor switch.
NO
Recheck from
beginning.