Inner And Outer Door Panels And Door Handle; Door Striker; Door Seal - ALLIANCE AE9133 Service Manual

Ae/ag/ne/ng series home laundry dryers
Table of Contents

Advertisement

To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the dryer(s) before servicing.
• Close gas shut-off valve to gas dryer(s) before servicing.
• Never start the dryer(s) with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the dryer is properly grounded.
30. INNER AND OUTER DOOR PANELS AND
DOOR HANDLE
a. Remove four screws holding hinges to door.
Refer to Figure 10.
b. Remove screws holding handle to door and
separate panels. Refer to Figure 11.
IMPORTANT: Do not over-tighten screws when
reinstalling door handle and avoid scratching inner
door panel.
DOOR
HANDLE
DOOR PANEL
60549
INNER
DOOR PANEL
OUTER
PHILLIPS HEAD
SCREW
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
WARNING

31. DOOR STRIKER

Refer to Figure 11
a. Remove two screws holding handle to door.
b. Spread door panels just far enough to depress
tabs on top and bottom of striker and push out
of inner panel.

32. DOOR SEAL

Open loading door and remove seal from inner
door panel.
NOTE: When replacing seal, be sure seal is not
stretched or distorted. Use a heat resistant adhesive
(such as Krazy Glue
door panel.
DOOR
HEX HEAD
STRIKER
SCREW
PHILLIPS HEAD
Figure 11
Section 5 Service Procedures
) to adhere door seal to inner
DOOR
SEAL
ASSEMBLY
SPEED
NUT
SCREW
DOOR
HINGE
DRY850S
W001R1
DOOR
27

Advertisement