Symptom: Failure Symptom; Troubleshooting - ALLIANCE AE9133 Service Manual

Ae/ag/ne/ng series home laundry dryers
Table of Contents

Advertisement

Section 8 Service Procedures Unique to Electronic Control Model Dryers
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the dryer(s) before servicing.
• Close gas shut-off valve to gas dryer(s) before servicing.
• Never start the dryer(s) with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the dryer is properly grounded.

78. SYMPTOM: FAILURE SYMPTOM

Diagnostic Cycle.
Dryer plugged in.
All LED's should be off.
Press and hold SIGNAL VOLUME,
then press GO.
Do all numbers appearing in the
display window correspond with
the appropriate LED's listed in
Figure 60, Self-Diagnostic
Routine?
Proceed to the appropriate
flow charts for the "SYMPTOM."
NOTE: The DIAGNOSTIC cycle follows the
Diagnostic Routine located behind the control hood.
All numbers should match with the correct LED's.
Refer to Figure 60.
NOTE: Refer to Figure 59.
If the symptom or problem corresponds to one of
the symptoms detailed on the following pages,
proceed to that flow chart. (The diagnostic cycle
check does not have to be made.)
80
YES

Troubleshooting

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
WARNING
NO
Broken, loose or
incorrect wiring?
YES
Correct
wiring.
W001R1
NO
Replace
control.
60549