Connect Electrical Plug (Electric Dryer Only); Grounding Information - ALLIANCE Dryers Installation Instructions Manual

Table of Contents

Advertisement

1
5
4
1. New Stainless Steel Flexible Connector – (Use design
CSA certified connector) Use only if allowed by local co-
des
2. 1/8 in. NPT Pipe Plug
3. Equipment Shut-Off Valve
4. Black Iron Pipe:
Shorter than 20 ft. [6.1 m] – Use 3/8 in. [9.5 mm] pipe.
Longer than 20 ft. [6.1 m] – Use 1/2 in. [12.7 mm] pipe.
5. 3/8 in. NPT Gas Connection
4. Tighten all connections securely but don't overtighten to
avoid breaking or bending the gas valve bracket. Turn on gas
and check all pipe connections (internal & external) for gas
leaks with a non-corrosive leak detection fluid.
NOTE: The dryer and its appliance main gas valve must
be disconnected from the gas supply piping system
during any pressure testing of that system at test pres-
sures in excess of 1/2 psi [3.45 kPa]. Refer to Check
Heat Source.
NOTE: DO NOT connect the dryer to L.P. Gas Service
without converting the gas valve. Install L.P. Gas Con-
version Kit 649P3, available at extra cost.
L.P. (Liquefied Petroleum) Gas, 2500 Btu/ft.
service must be supplied at 10 ± 1.5 inch water column pressure.
For proper operation at altitudes above 3000 feet [915 m] the L.P.
gas valve spud orifice size must be reduced to ensure complete
combustion. Refer to Table 4 .
Part No. 510963R7
2
3
D233I_SVG
Figure 5
3
3
[93.1 MJ/m
©
Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT
L.P. Altitude Adjustments
Altitude
feet [m]
3000 [915]
8000 [2440]
Connect Electrical Plug (Electric Dryer
Only)
Dryer requires 120/240 Volt or 120/208 Volt, 60 Hertz, 3 wire
electrical supply. Refer to serial plate for specific electrical re-
quirements.
IMPORTANT: Use only a new U.L. listed No. 0 (copper
wire only) three conductor power supply cord kit rated
240 Volts (minimum) 30 Amperes and labeled as suita-
ble for use in a clothes dryer.
NOTE: The wiring diagram is located in the control
hood.
To reduce the risk of fire, electric shock, serious in-
jury or death, all wiring and grounding MUST con-
form with the latest edition of the National Electrical
Code, ANSI/NFPA 70, or the Canadian Electrical
Code, CSA C22.1, and such local regulations as
might apply. It is the customer's responsibility to
have the wiring and fuses installed by a qualified
electrician to make sure adequate electrical power is
available to the dryer.
],

Grounding Information

This dryer must be properly connected to a grounded metal, per-
manent wiring system; or an equipment-grounding conductor
must be run with the circuit conductors and connected to the
equipment-grounding terminal or lead on the dryer.
The dryer has its own terminal block that must be connected to a
separate branch, 60 Hertz, single phase circuit, AC (alternating
current) circuit, fused at 30 Amperes (the circuit must be fused on
both sides of the line). Electrical service for the dryer should be
Orifice Size
inches
No.
[mm]
55
0.0520
[1.32]
56
0.0465
[1.18]
Table 4