Section 5 Service Procedures
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the dryer(s) before servicing.
• Close gas shut-off valve to gas dryer(s) before servicing.
• Never start the dryer(s) with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the dryer is properly grounded.
ELEMENT
ATTACHING
SCREW
LIMIT
THERMOSTAT
Through Serial No. S6271975XG
BURNER
TUBE
GAS VALVE
HANDLE
BASE

43. HEATER ASSEMBLY

a. Remove two screws from the bottom edge of
the front panel. Refer to Figure 12.
b. Swing the bottom of the panel away from the
dryer to disengage hold-down clips and guide
lugs from cabinet top. Refer to Figure 12.
c. Disconnect wires from door switch. Refer to
Figure 13.
NOTE: Refer to the appropriate wiring diagram
when rewiring the switch.
36
ELEMENT
AND PLATE
Electric Models
DRY1797S
LIMIT THERMOSTAT
(Through Serial No.
S6333959XM)
BURNER
TUBE
SCREW
BURNER
HOUSING
SCREW
DRY855S
Gas Models
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
WARNING
LIMIT
THERMOSTAT
THERMAL
FUSE
Starting Serial No. S6271976XG
GAS VALVE
HANDLE
BASE
Figure 19
d. Remove two screws holding element and plate
to heater box and pull element down and away
from heater box. Refer to Figure 19.
e. Disconnect wires from element and plate.
f. Remove screws holding thermostat (and
thermal fuse, if present) to element and plate.
Refer to Figure 19.
NOTE: When reassembling, be sure all wire
connectors are tight on element terminals, thermal
fuse and limit thermostat.
ELEMENT
AND PLATE
ELEMENT
D243S
ATTACHING
SCREW
LIMIT THERMOSTAT
BURNER
(Starting Serial No.
TUBE
S6333960XM)
D244S
BURNER
SCREW
HOUSING
W001R1
BURNER
TUBE
SCREW
60549