Gas Burner Conversion Procedures
For converting dryers equipped for L.P. gas to Natural gas
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the dryer(s) before servicing.
• Close gas shut-off valve to gas dryer(s) before servicing.
• Never start the dryer(s) with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the dryer is properly grounded.
This conversion kit is to be installed by AUTHORIZED DEALERS or DISTRIBUTORS on their
premises and in accordance with the manufacturer's instructions and all codes and
requirements of the authority having jurisdiction. Failure to follow instructions could result in
serious injury or property damage. The qualified agency performing this work assumes
responsibility for this conversion.
402P3 Natural Gas Conversion Kit consists of:
1 - 58719
Burner Orifice Spud Metal stamped
#44)
1 - 58768
Vent Screw
1 - 60514
Conversion Plate
1 - 60516
Valve Converted to Natural Gas
Sticker
2 - 60521
Natural Gas Stickers
Gas Input - 20,000 BTU/HR
NOTE: When converting the dryer gas valve to
Natural Gas, be sure the incoming gas supply line is
equipped with a pressure regulator (located ahead
of the dryer) that will maintain the gas supply to the
dryer at 6.5 ± 1.5 inches (16.5 ± 3.81 cm) water
column pressure and a vent to the outdoors must be
provided. Remove pressure tap pipe plug and check
gas pressure by connecting a "U " tube manometer
(or similar pressure gauge) to the pressure tap .
Refer to Figure 45.
60549
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
WARNING
WARNING
Vent Screw
MANOMETER
DRY966S
Burner Orifice Spud
6.5 ± 1.5
INCHES
DRY961S
PRESSURE
TAP
Figure 45
W001R1