To Test Door Switch; Striker Catch; Door Hinge; Hold-Down Clips And Guide Lugs - ALLIANCE AE9133 Service Manual

Ae/ag/ne/ng series home laundry dryers
Table of Contents

Advertisement

To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the dryer(s) before servicing.
• Close gas shut-off valve to gas dryer(s) before servicing.
• Never start the dryer(s) with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the dryer is properly grounded.

To Test Door Switch

1. Disconnect wires from door switch. Refer to
Figure 13.
NOTE: Refer to appropriate wiring diagram
when rewiring switch.
2. Set meter or read Ohms and apply meter probes
on switch terminals 1 and 3 with door closed.
You should get "zero" reading.
3. Apply probes to terminals 1 and 2 with door
closed. The meter should read "infinite".
4. Open door. Meter should read "infinite"
between 1 and 3 and "zero" between 1 and 2.

35. STRIKER CATCH

a. Remove two screws from the bottom edge of
the front panel. Refer to Figure 12.
b. Swing the bottom of the panel away from the
dryer to disengage hold-down clips and guide
lugs from cabinet top. Refer to Figure 12.
c. Disconnect wires from door switch. Refer to
Figure 13.
NOTE: Refer to the appropriate wiring diagram
when rewiring the switch.
d. Depress tabs on top and bottom of catch and
push out of front panel. Refer to Figure 12.
60549
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
WARNING

36. DOOR HINGE

a. Open loading door and remove four screws
holding door assembly to hinges. Refer to
Figure 10.
b. Remove two screws from the bottom edge of
the front panel. Refer to Figure 12.
c. Swing the bottom of the panel away from the
dryer to disengage hold-down clips and guide
lugs from cabinet top. Refer to Figure 12.
d. Disconnect wires from door switch. Refer to
Figure 13.
NOTE: Refer to the appropriate wiring diagram
when rewiring the switch.
e. Remove four screws and locknuts holding
hinges to front panel. Refer to Figure 12.

37. HOLD-DOWN CLIPS AND GUIDE LUGS

a. Remove two screws from the bottom edge of
the front panel. Refer to Figure 12.
b. Swing the bottom of the panel away from the
dryer to disengage hold-down clips and guide
lugs from cabinet top. Refer to Figure 12.
c. Disconnect wires from door switch. Refer to
Figure 13.
NOTE: Refer to the appropriate wiring diagram
when rewiring the switch.
d. Compress hold-down clips and remove from
slot in top flange of front panel. Refer to
Figure 12.
e. Remove four screws holding four guide lugs to
front panel. Refer to Figure 12.
Section 5 Service Procedures
W001R1
29

Advertisement

Table of Contents
loading