Orban OPTIMOD 6300 Operating Manual page 92

Digital multipurpose audio processor, version 2.3 software
Hide thumbs Also See for OPTIMOD 6300:
Table of Contents

Advertisement

2-38
INSTALLATION
If silence is detected at the analog input as well as the digital input (as in
the case of a studio operational fault), automatic switching will not oc-
cur.
When an active signal is restored to the digital input, the 6300 will
automatically switch back to that input.
This feature is unavailable in the 6300's audio processing mode.
A) Navigate to S
ETUP
to the level below which the 6300 will interpret the input as being silent.
This setting is with respect to the current analog reference level and digi-
tal reference level.
B) Press N
as necessary to see the S
EXT
of time that the input must be below the Silence Threshold before the 6300
automatically switches to the analog input.
C) Press N
as necessary to see the A
EXT
wish the 6300 to switch automatically from the digital to analog input when
silence is detected. Set the control to N
21. Program Tally Outputs.
[Skip this step if you do not wish to use the tally outputs.]
See step 6 on page 2-4 for wiring instructions.
You can program the two tally outputs to indicate a number of different opera-
tional and fault conditions.
A) Navigate to S
ETUP
B) Program tally output #1.
To program a given tally output, press and hold the soft button associ-
ated with the output you are programming. As you turn the control
knob, the functions listed below will appear in the highlighted field.
 Input: Analog: Indicates that the 6300 is processing audio from its analog
input.
 Input: Digital: Indicates that the 6300 is processing audio from its AES3
digital input.
 Analog Input Silent: Indicates that the level at either or both analog in-
put channels is below the threshold set in step 16 on page 2-28.
 AES Input Silent: Indicates that the level at either or both digital input
channels is below the threshold set in step 16 on page 2-28.
 AES Input Error: Indicates that the 6300's AES input receiver chip has de-
tected that the input data is unusable. When the chip detects such an error,
it automatically switches the in-put to ANALOG.
 No Function: Tally output is disabled.
> T
>
ALLY
SILENCE THRESHOLD
ILENCE
NALOG
O
> T
> T
O
1.
ALLY
ALLY
UT
ORBAN MODEL 6300
and set the Silence Threshold
D
ELAY
control. Set it to the amount
F
control. Set it to Y
ALLBACK
to defeat automatic switching.
if you
ES

Advertisement

Table of Contents
loading

Table of Contents