6-4
TECHNICAL DATA
Termination: Unterminated. For wordclock, use an external 75 terminator if the 6300 is
the last item in the chain. For AES11id, always use a 75 terminator.
Remote Computer Interface
Configuration: TCP/IP protocol via direct cable connect, modem, or Ethernet interface.
Modem is not supplied.
Serial Port: 115 kbps RS–232 port DB–9 male, EMI-suppressed.
Ethernet Port: 100 Mbit / sec on RJ45 female connector.
Remote Control (GPI) Interface
Configuration: Eight (8) inputs, opto-isolated and floating.
Voltage: 6–15V AC or DC, momentary or continuous. 12 VDC provided to facilitate use with
contact closure.
Connector: DB–25 male, EMI-suppressed.
Control: User-programmable for any eight of user presets, factory presets, bypass, test
tone, stereo or mono modes, analog input, digital input.
Filtering: RFI filtered.
Tally Outputs
Circuit Configuration: Two NPN open-collector outputs.
Voltage: +15 volts maximum. Do not apply negative voltage. When driving a relay or other
inductive load, connect a diode in reverse polarity across the relay coil to protect the
driver transistors from reverse voltage caused by inductive kickback.
Current: 30 mA maximum
Indications: Tally outputs can be programmed to indicate a number of different operational
and fault conditions, including Input: Analog, Input: Digital, Analog Input Silent, AES In-
put Silent, and AES Input Error.
Power
Voltage: 85–264 VAC, 50–60 Hz, 30 VA.
Connector: IEC, EMI-suppressed. Detachable 3-wire power cord supplied.
Fuse: 2.5A 20mm Quick Acting HBC, mounted on the power supply circuit board.
Grounding: Circuit ground is independent of chassis ground, and can be isolated or con-
nected with a rear panel switch.
Safety Standards: ETL listed to UL standards, CE marked.
Environmental
Operating Temperature: 32 to 122 F / 0 to 50 C for all operating voltage ranges.
Humidity: 0–95% RH, non-condensing.
Dimensions (W x H x D): 19" x 1.75" x 14.25" / 48.3 cm x 4.5 cm x 36.2 cm. One rack unit
high.
Humidity: 0–95% RH, non-condensing.
RFI / EMI: Tested according to Cenelec procedures. FCC Part 15 Class A device.
Shipping Weight: 10 lbs / 4.6 kg