Detaching And Refitting The Pwb. (Hvpwb) - Kyocera ECOSYS M3040dn Service Manual

Hide thumbs Also See for ECOSYS M3040dn:
Table of Contents

Advertisement

(4) Detaching and refitting the PWB. (HVPWB)

Procedure
1. Remove the upper interface cover.
2. Release two hooks using a flat screw
driver and remove the right stay cover.
3. Remove the controller cover.
4. Open the front cover.
5. Remove the screw from the right upper
cover.
6. Release two hooks using a flat screw
driver and remove the right upper cover.
Upper
interface cover
Right upper cover
Flat screw driver
Controller cover
2-2-36
2NM/2NX/2NY/2NZ/2P0/2P6-1
Right stay cover
Hooks
Flat screw driver
Figure 2-2-37
Hooks
Screw
Figure 2-2-38