Setting: Tb2 time out

In the fax/telephone auto select mode, sets the time to start ringing an operator through the con-
nected telephone after receiving a call as a fax machine (see figure 1-3-18). In the fax/telephone
auto select mode, change the setting when fax reception is unsuccessful or a telephone fails to
receive a call.
1. Change the setting using the cursor right/left keys.
Tb2 time-out time
2. Press the start key. The value is set.

Setting: Tc time out

In the TAD mode, set the time to check if there are any triggers for shifting to fax reception after a
connected telephone receives a call. Only the telephone function is available if shifting is not made
within the set Tc time.
In the TAD mode, change the setting when fax reception is unsuccessful or a telephone fails to
receive a call.
1. Change the setting using the cursor right/left keys.
Tc time-out time
2. Press the start key. The value is set.

Setting: Td time out

Sets the length of the time required to determine silent status (fax), one of the triggers for Tc time
check. In the TAD mode, change the setting when fax reception is unsuccessful or a telephone
fails to receive a call. Be sure not to set it too short; otherwise, the mode may be shifted to fax
while the unit is being used as a telephone.
1. Change the setting using the cursor right/left keys.
Td time-out time
2. Press the start key. The value is set.
Completion
Press the stop key. The screen for selecting a maintenance item No. is displayed.
Description
Description
Description
1-3-85
2NM/2NX/2NY/2NZ/2P0/2P6
Setting range
Initial setting
1 to 255
Setting range
Initial setting
1 to 255
Setting range
Initial setting
1 to 255
9 (120 V)/
6 (220-240 V)
100 ms
60