14. Remove the drive belt from two pulleys.
15. Remove the carriage assembly , ISU
shaft and the lower ISU frame upward.
16. Pull the carriage assembly out.
17. Remove the drive belt from the holding
part of the carriage assembly.
18. Check or replace the exposure lamp
and refit all the removed parts.
Carriage
assembly
Pulley
Drive belt
Holding part
1-5-19
2NM/2NX/2NY/2NZ/2P0/2P6
ISU shaft
Lower ISU frame
Pulley
Drive belt
Figure 1-5-29
Carriage
assembly
Drive belt
Figure 1-5-30
ISU shaft