16. Remove the connector cover B by
releasing the hook.
17. Remove the screw of connector cover
C.
18. Remove the connector cover C by
releasing the hook.
19. Pull two connectors out.
20. Remove the grounding wire by remov-
ing the screw.
21. Remove the connector from the power
source PWB.
22. Remove three screws and then remove
the power source PWB assembly.
23. Check or replace the power source
PWB and refit all the removed parts.
Screw
Hook
Connector cover C
Grounding wire
Connector
2-2-51
2NM/2NX/2NY/2NZ/2P0/2P6
Connector cover B
Hook
Connectors
Figure 2-2-64
Power source PWB
assembly
Screw
Screw
Screw
Figure 2-2-65
Screw