Kyocera ECOSYS M3040dn Service Manual page 185

Hide thumbs Also See for ECOSYS M3040dn:
Table of Contents

Advertisement

Code
Contents
0870
PCFAX control PWB to main
PWB high capacity data
transfer error
High-capacity data transfer
between the FAX control PWB
and the main PWB of the
machine was not normally
performed even if the data
transfer was retried the speci-
fied times.
0920
Fax file system error
The backup data is not
retained for file system abnor-
mality of flash memory of the
FAX control PWB.
0970
24 V power down detect
If a 24V power disconnection
signal is observed and a 12V
power disconnection signal is
observed simultaneously for
one second.
1010
Lift motor error
(50/60 ppm model only)
After cassette 1 is inserted, lift
sensor does not turn on within
10 s. This error is detected
four times successively.
Related parts
FAX control PWB
Control PWB
Replace the control PWB and check for
correct operation (see page 2-2-12).
FAX control PWB
Connect right PWB
Control PWB
Replace the control PWB (see page 2-2-12)
Bottom plate ele-
Check to see if the bottom plate can move
vation mechanism
smoothly and repair it if any problem is
in the cassette
found.
Connector cable or
Reinsert the connector. Also check for conti-
poor contact in the
nuity within the connector cable. If none,
connector
replace the cable.
Lift motor and connect right PWB (YC9)
Connect right PWB and control PWB (YC29)
Drive transmission
Check if the gears rotate smoothly. If not,
system of the lift
grease the bushes and gears. Check for
motor
broken gears and replace if any.
Lift motor
Replace the lift motor.
Connect right PWB Replace the connect right PWB (see page 2-
2-31).
Control PWB
Replace the control PWB and check for cor-
rect operation (see page 2-2-12).
1-4-23
2NM/2NX/2NY/2NZ/2P0/2P6
Check procedures/
corrective measures
1. Turn the main power swtch off and after
5 seconds, re-mount the FAX controller
PWB, then turn power on.
2. Replace the FAX control PWB.
1. Execute initializing by U600 (Refer to
the FAX service manual).
2. Replace the FAX control PWB.
1. Check the +24V output is given at YC4-
10 to 13 of the connect right PWB.
2. Replace the connect right PWB (see
page 2-2-31)

Hide quick links:

Advertisement

Table of Contents

Troubleshooting

loading

Table of Contents