Code
Contents
2200
Drum motor drive error
(50/60 ppm model only)
The drum motor is not stabi-
lized within 2 s after driving
starts.
2210
Drum motor steady-state
error
(50/60 ppm model only)
Stable OFF is detected for 2 s
continuously after drum motor
stabilized.
2330
Envelope motor error
(Over-current)
(50/60 ppm model only)
The over-current detection
signal of the motor is detected
continuously twenty times.
Related parts
Connector cable or
Reinsert the connector. Also check for conti-
poor contact in the
nuity within the connector cable. If none,
connector
replace the cable.
Drum motor and connect right PWB (YC10)
Connect right PWB and control PWB (YC29)
Drive transmission
Check if the rollers and gears rotate
system of the drum
smoothly. If not, grease the bushes and
motor
gears. Check for broken gears and replace if
any.
Drum motor
Replace the drum motor.
Connect right PWB Replace the connect right PWB (see page 2-
2-31).
Control PWB
Replace the control PWB and check for cor-
rect operation (see page 2-2-12).
Connector cable or
Reinsert the connector. Also check for conti-
poor contact in the
nuity within the connector cable. If none,
connector
replace the cable.
Drum motor and connect right PWB (YC10)
Connect right PWB and control PWB (YC29)
Drive transmission
Check if the rollers and gears rotate
system of the drum
smoothly. If not, grease the bushes and
motor
gears. Check for broken gears and replace if
any.
Drum motor
Replace the drum motor.
Connect right PWB Replace the connect right PWB (see page 2-
2-31).
Control PWB
Replace the control PWB and check for cor-
rect operation (see page 2-2-12).
Connector cable or
Reinsert the connector. Also check for conti-
poor contact in the
nuity within the connector cable. If none,
connector
replace the cable.
Envelope motor and connect left PWB
(YC11)
Connect left PWB and control PWB (YC2)
Drive transmission
Check if the gears rotate smoothly. If not,
system of the
grease the bushes and gears. Check for
envelope motor
broken gears and replace if any.
Envelope motor
Replace the envelope motor.
Connect left PWB.
Replace the connect left PWB (See Page 2-
2-20).
Control PWB
Replace the control PWB and check for cor-
rect operation (See Page 2-2-12).
1-4-28
2NM/2NX/2NY/2NZ/2P0/2P6
Check procedures/
corrective measures

Hide quick links: