(14) Image center does not align with the original center.

Print example
1. Table scanning
Defective part
Original document
1
Contact glass assy Check the location the contact
2
Adjustment of the
scanner
3
2. DP-scanning
Defective part
Original document
1
Adjustment of the
scanner
2
Check description
Check if the original document is
loaded correctly on the contact
glass.
glass is mounted.
Check the scanning adjustment
of the scanner.
Check description
Check if the original document is
loaded correctly in the DP.
Check the scanning adjustment
of DP scanning.
If the original document is not properly placed
on the contact glass, place it correctly.
Re-mount the contact glass if it is hanged off.
1. Perform maintenance mode U067,
Front.(see page 1-3-30)
2. Perform maintenance mode U411,
Table(Chart1)_Input.
(see page 1-3-54)
If the original document is not properly placed
in the DP, place it correctly.
1. Perform maintenance mode U072.
2. Perform maintenance mode U411, DP
FaceUp(Chart2)_Input. (see page 1-3-54)