(4) Detaching and refitting the PWB. (OPPWB)
Procedure
1. Raise the operation panel assembly by
releasing four hooks using a flat screw
driver.
2. Remove the connector and FFC from
the operation panel PWB.
3. Remove twelve screws.
4. Release thirteen hooks and then
remove the operation panel PWB.
5. Check or replace the operation panel
PWB and refit all the removed parts.
*: Be careful not to lose a spring.
Flat screw driver
Screws
Hooks
Hooks
2-2-60
2NM/2NX/2NY/2NZ/2P0/2P6
Operation panel
assembly
Hooks
Connector
FFC
Figure 2-2-73
Screws
Operation
panel PWB
Figure 2-2-74
Operation
panel cover

Hide quick links: