1-5-9 PWBs

(1) Detaching and refitting the control PWB

Procedure
1. Remove the FAX control PWB.
(See page 1-5-48)
2. Remove the right cover.
(See page 1-5-3)
3. Remove the five connectors from the
scanner PWB.
4. Remove twenty connectors and two
FFCs from the control PWB.
5. Remove the wires from the clamp.
Connectors
Scanner PWB
Control PWB
YC6
YC29
YC28
(FFC)
U17
YC32
YC24
YC10
YC12
YC27
YC27
YC2013
YC9
YC18 YC26
YC21
YC13
YC20
YC17
YC16
YC25
YC30
YC23
Connectors
Figure 1-5-55
1-5-37
2PK/2PL/2PM/2PN
YC104
YC108
YC105
Scanner PWB
Wires
Control PWB
Clamp
YC8
YC7
YC3
(FFC)
YC2005
YC2007
YC2000
1
8
11
YS2000
YC2010
YC19
FFCs
YC109
YC101
YC2014
YC2006
12
YC2004

Hide quick links: