(2) Detaching and refitting the paper feed driving motor unit

Procedure
1. Remove right middle cover.
(See page 1-5-90)
2. Remove right lower cover.
(See Page 1-5-91)
3. Pull the connectors of clutches and
solenoid out.
4. Remove three screws and then remove
the paper feed driving motor unit.
5. Check or replace the paper feed driving
motor unit and refit all the removed
parts.
Paper feed drive unit
Figure 1-5-163