6120
Abnormally high fuser
thermistor 1 temperature
(50/60 ppm model)
The detection temperature of
fuser thermistor 1 is higher
than 245°C/473°F.
In a heater-off state, the
detection temperature of fuser
thermistor 1 is higher than
195°C/383°F after the detec-
tion temperature of fuser
thermistor 1 was 155°C/311°F
or less.
(40 ppm model)
The detection temperature of
fuser thermistor 1 is higher
than 250°C/482°F.
In a heater-off state, the
detection temperature of fuser
thermistor 1 is higher than
170°C/338°F after the detec-
tion temperature of fuser
thermistor 1 was 155°C/311°F
or less.
6130
Broken fuser thermistor 1
wire
(50/60 ppm model only)
A/D value of the fuser thermis-
tor 1 exceeds 1019 bit contin-
uously for 4 s during warming
up.
Related parts
Connector pin
See page 1-4-36.
Triac
See page 1-4-36.
Fuser thermistor
Replace the fuser unit (see page 1-5-44).
Contrl PWB
Replace the control PWB and check for cor-
rect operation (see page 2-2-12).
Connector cable or
Reinsert the connector. Also check for conti-
poor contact in the
nuity within the connector cable. If none,
connector
replace the cable.
Fuser thermistor and fuser thermistor con-
nect PWB (YC1)
Fuser thermistor connect PWB and control
PWB (YC21)
Connector pin
See page 1-4-36.
Triac
See page 1-4-36.
Fuser thermistor
Replace the fuser unit (see page 1-5-44).
Fuser thermistor
Replace the fuser thermistor connect PWB.
connect PWB
Control PWB
Replace the control PWB and check for cor-
rect operation (see page 2-2-12).
1-4-37
2NM/2NX/2NY/2NZ/2P0/2P6
Check procedures/
corrective measures