Parameter list
Parameter
Name
Monitor display and monitor output signal — Adjustment of terminal FM and AM
(calibration) (C0(Pr.900), C1(Pr.901))
C0
FM terminal
(900)
calibration
C1
AM terminal
(901)
calibration
C2 (902)
to
Refer to Pr.125 and Pr.126.
C7 (905)
C42 (934)
to
Refer to Pr.127 to Pr.134.
C45 (935)
The parameter number in parentheses is the one for use with the parameter unit (FR-PU04/FR-PU07).
Useful functions — Parameter copy alarm release (Pr.989)
Parameter copy
989
alarm release
* The setting depends on the inverter capacity (55K or lower/75k or higher)
Setting of the parameter unit and operation panel — Buzzer control of the operation panel
(Pr.990)
990
PU buzzer control
Setting of the parameter unit and operation panel — PU contrast adjustment (Pr.991)
PU contrast
991
adjustment
Useful functions — Fault initiation (Pr.997)
997
Fault initiation
114
Incre-
Initial
Range
ments
Value
---
---
---
---
---
---
1
10/100
10/100 *
*
0
1
1
1
1
58
0 to 63
16 to 18,
32 to 34, 48,
49, 64, 80 to
82, 96, 97,
112, 128,
129, 144,
145, 160,
161,
1
9999
176 to 179,
192 to 194,
196 to 199,
230, 241,
245 to 247,
253
9999
Description
Calibrate the scale of the meter connected to
terminal FM.
Calibrate the scale of the analog meter
connected to terminal AM.
Parameters for alarm release at parameter
copy
Without buzzer
With buzzer
Contrast adjustment of the LCD of the
parameter unit (FR-PU04/FR-PU07) can be
performed.
0 (Light) → 63 (Dark)
The setting range is same with the one for
fault data codes of the inverter (which can
be read through communication). (Refer to
page 117)
Written data is not stored in EEPROM.
The read value is always "9999."
This setting does not initiate a fault.
: enabled
× : disabled
×
×
×
×