Operation panel (FR-DU07)
4.1.5

Monitoring of output current and output voltage

POINT
Monitor display of output frequency, output current and output voltage can be changed by pushing
monitoring mode.
1.
Press
frequency monitor
2.
Independently of whether the inverter is running
in any operation mode or at a stop, the output
current monitor appears by pressing
3.
Press
REMARKS
⋅ Monitored item can be changed from output voltage to other items such as output power and set frequency by setting Pr.52.
Refer to Chapter 4 of
4.1.6

First priority monitor

Hold down
for 1s to set monitor description to be appeared first in the monitor mode.
(To return to the output frequency monitor, hold down
4.1.7

Displaying the set frequency

Press the setting dial (
"3") to show the set frequency.
50
Operation
during operation to choose the output
to show the output voltage monitor.
the Instruction Manual (Applied).
) in the PU operation mode or in the External/PU combined operation mode 1 (Pr. 79 =
Display
.
for 1s after displaying the output frequency monitor.)