Simple mode parameter list
Parameter
Name
Number
IPM parameter
998
initialization
Automatic
999
parameter setting
*1
Initial values differ according to the inverter capacity. (0.75K/1.5K to 3.7K/5.5K, 7.5K/11K to 37K/45K, 55K/75K or higher)
*2
Initial values differ according to the inverter capacity. (55K or lower/75K or higher)
*3
Performing IPM parameter initialization changes the settings. (Refer to page 43)
*4
Initial values differ according to the inverter capacity. (7.5K or lower/11K or higher)
*5
Setting increments and setting range differ according to the inverter capacity. (55K or lower/75K or higher)
72
Incre
Initial
Range
ments
Value
0, 1, 12, 101,
1
0
112
10, 11, 20, 21,
1
9999
30, 31, 9999
Applications
By performing IPM parameter initialization, IPM
motor control is selected and the parameters,
which are required to drive an IPM motor, are
changed.
Parameter settings are changed as a batch.
Those include communication parameter
settings for a Mitsubishi human machine
interface (GOT) connection, rated frequency
settings of 50Hz/60Hz, and acceleration/
deceleration time increment settings.
Refer
to
43
115