Setting procedure of IPM motor control
<IPM>
(1) IPM motor control setting by selecting the parameter setting mode on the operation panel
(
)
POINT
· The parameters required to drive an IPM motor are automatically changed as a batch. (Refer to page 43.)
Initialize the parameter setting for a premium high-efficiency IPM motor (MM-EFS) by selecting the parameter
Operation example
setting mode on the operation panel.
1.
Screen at power-ON
The monitor display appears.
2.
Parameter setting mode
Press
mode.
3.
Selecting the parameter
Turn
initialization) appears.
4.
Displaying the setting
Press
"
" (initial value) appears.
5.
Selecting the setting
Turn
6.

Parameter setting

Press
Turn
Setting
0
Parameter settings for a general-purpose motor
1
Parameter settings for a high-efficiency IPM motor MM-EF (rotations per minute)
12
Parameter settings for a premium high-efficiency IPM motor MM-EFS (rotations per minute)
REMARKS
· Performing IPM parameter initialization by selecting the parameter setting mode on the operation panel automatically changes
the Pr. 998 IPM parameter initialization setting.
· The parameter initialization sets the same capacity as the inverter capacity to Pr. 80 Motor capacity. To use a 0.4kW MM-EF, set Pr. 80
Motor capacity = "0.4" before performing IPM parameter initialization by selecting the parameter setting mode on the operation panel.
· The IPM parameter setting is displayed as "1, 12" in the parameter setting mode even if Pr.998 IPM parameter initialization = "101, 112."
(2) IPM motor control display and IPM motor control signal
P.RUN on the operation panel (FR-DU07) is lit and the IPM motor control signal (IPM) is output during IPM motor control.
For the terminal to output the IPM motor control signal, assign the function by setting "57 (positive logic)" or "157
(negative logic)" to any of Pr.190 to Pr.196 (Output terminal function selection).
42
Operation
to choose the parameter setting
until
(IPM parameter
to read the currently set value.
to change it to the set value "
to set.
to read another parameter.
Press
to show the setting again.
Press
twice to show the automatic parameter setting (AUTO).
Display
".
Flicker ... Parameter setting complete!!
P.RUN indicator is lit.
Description
The parameter
number read
previously appears.