Yamaha FJR1300R Service Manual page 187

Yamaha motorcycles service manual
Hide thumbs Also See for FJR1300R:
Table of Contents

Advertisement

CHECKING AND CHARGING THE BATTERY
Relationship between the open-circuit voltage and the
charging time at 20 °C
Charging time (hours)
These values vary with the temperature, the condition of the battery
plates, and the electrolyte level.
NOTE:
@
Since MF batteries are sealed, it is not possi-
ble to check the charge state of the battery by
measuring the specific gravity of the electro-
lyte. Therefore, the charge of the battery has to
be checked by measuring the voltage at the
battery terminals.
1. Remove:
• right inner panel (front cowling)
Refer to "COWLINGS AND COVERS".
2. Disconnect:
• battery leads
(from the battery terminals)
CAUTION:
@
First, disconnect the negative battery lead
1, and then the positive battery lead 2.
3. Remove:
• battery
4. Measure:
• battery charge
M
MMM
M MMM
M
M MMM
M
a. Connect a pocket tester to the battery termi-
nals.
Positive tester probe →
Negative tester probe →
NOTE:
@
• The charge state of an MF battery can be
checked by measuring its open-circuit volt-
age (i.e., the voltage when the positive bat-
tery terminal is disconnected).
• No charging is necessary when the open-cir-
cuit voltage equals or exceeds 12.8 V.
b. Check the charge of the battery, as shown
in the charts and the following example.
Example
c. Open-circuit voltage = 12.0 V
d. Charging time = 6.5 hours
e. Charge of the battery = 20 ~ 30%
L
LLL
L LLL
L
L LLL
L
3 - 71
CHK
ADJ
M MMM
M
M MMM
M
M MMM
M
MMM
positive battery terminal
negative battery terminal
L LLL
L
L LLL
L
L LLL
L
LLL