(5) Function assignment to analog input terminal 1, terminal 4, and terminal 6 (FR-A7AZ)
Functions of terminal 1, terminal 4, and terminal 6
(FR-A7AZ) of analog input can be selected and
changed by parameter.
For the terminal 1, terminal 4, and terminal 6 (FR-
A7AZ) used for analog input, frequency (speed)
[Pr.]
High resolution analog input
406
selection
858
Terminal 4 function assignment
868
Terminal 1 function assignment
Terminal 1 function according to control
V/F Control,
[Pr. 868]
Advanced Magnetic Flux
setting
Vector Control
0
(initial
Frequency setting auxiliary
value)
1
*1
2
3
Stall prevention operation level
4
*1
5
6
9999
Terminal 4 function according to control
[Pr. 858]
V/F Control, Advanced
Setting
Magnetic Flux Vector Control
0
Frequency command
(initial
(AU signal-ON)
value)
1
*1 *2
Stall prevention operation level input
4
*1 *2
9999
: No function
*1
When the same value (1 or 4) is set in [Pr. 868, 858], terminal 1 is made valid and terminal 4 has no function.
*2
When [Pr. 858 = 1, 4], functions of terminal 4 become valid independently of whether the terminal AU is ON or OFF.
Name
Initial Value
Speed control
Speed setting auxiliary
Magnetic flux command
Regenerative torque
limit ([Pr. 810 = 1])
input
Torque bias input
[Pr. 840 = 1, 2, 3]
Speed control
Speed command
(AU signal-ON)
Magnetic flux command
command, torque command, etc. can be selected. In
addition, functions change according to the control
mode.
Setting Range
9999
0, 2 to 6, 9999
0
0, 1, 4, 9999
0
0 to 6, 9999
Real Sensorless Vector Control,
Vector Control
Torque control
Speed limit auxiliary
Magnetic flux command
Torque command
([Pr. 804 = 0]
Torque limit
Torque command
[Pr. 810 = 1]
([Pr. 804 = 0]
Forward/reverse rotation
speed limit
([Pr. 807 = 2]
Real Sensorless Vector Control,
Vector Control
Torque control
Speed limit
(AU signal-ON)
Magnetic flux command
Torque limit
[Pr. 810 = 1]
46
SPECIFICATIONS
Description
Selection of terminal 6 function
(refer to the table below)
Selection of terminal 4 function
(refer to the table below)
Selection of terminal 1 function
(refer to the table below)
Vector Control
Position control
Magnetic flux command
Regenerative torque limit
[Pr. 810 = 1]
Torque limit
[Pr. 810 = 1]
Vector Control
Position Control
Magnetic flux command
Torque limit
[Pr. 810 = 1]