[Pr.]
Name
Setting Range
1 to 3, 5, 7 to 12, 14, 21, 24,
306
Analog output signal selection
52, 53, 61, 62
307
Setting for zero analog output
0 to 100%
308
Setting for maximum analog output
0 to 100%
Analog output signal voltage/current
309
0, 1, 10, 11
switchover
1 to 3, 5, 7 to 12, 14, 21, 24,
310
Analog meter voltage output selection
52, 53, 61, 62
Setting for zero analog meter voltage
311
0 to 100%
output
Setting for maximum analog meter voltage
312
0 to 100%
output
313
DO0 output selection
0, 1, 3, 4, 7, 8, 11 to 16, 20,
314
DO1 output selection
25, 26, 46, 47, 64, 90, 91,
315
DO2 output selection
93, 95, 96, 98, 99, 100, 101,
316
DO3 output selection
103, 104, 107, 108, 111 to
116, 120, 125, 126, 146,
317
DO4 output selection
147, 164, 190, 191, 193,
318
DO5 output selection
195, 196, 198, 199, 9999
319
DO6 output selection
320
RA1 output selection
0, 1, 3, 4, 7, 8, 11 to 16, 20,
321
RA2 output selection
25, 26, 46, 47, 64, 90, 91,
95, 96, 98, 99, 9999
322
RA3 output selection
323
AM0 0V adjustment
900 to 1100%
324
AM1 0mA adjustment
900 to 1100%
-
329
Digital input unit selection
0, 1, 2, 3
Communication operation command
338
0, 1
source
339
Communication speed command source
0, 1, 2
340
Communication startup mode selection
0, 1, 10
342
Communication EEPROM write selection
0, 1
343
Communication error count
-
345
DeviceNet address
0 to 4095
346
DeviceNet baud rate
0 to 4095
-
349
Communication reset selection
0, 1
387
Initial communication delay time
0 to 120s
388
Send time interval at heart beat
0 to 999.8s
389
Minimum sending time at heart beat
0 to 999.8s
390
% setting reference frequency
1 to 400Hz
391
Receive time interval at heart beat
0 to 999.8s
392
Event driven detection width
0.00 to 163.83%
450
Second applied motor
0, 1, 9999
PARAMETER
Minimum Setting
Refer to
Initial Value
Increments
Page
1
2
345
0.1%
0
357
0.1%
100
357
1
0
357
1
2
345
0.1%
0
357
0.1%
100
357
1
9999
61
1
9999
61
1
9999
61
1
9999
61
1
9999
61
1
9999
61
1
9999
61
1
0
61
1
1
61
1
4
61
1%
1000
357
1%
1000
357
1
1
229
1
0
436
1
0
436
1
0
434
1
0
443
1
0
459
1
63
1
132
1
0
0.1s
0s
0.1s
0s
0.1s
0.5s
0.01Hz
60Hz
0.1s
0s
0.01%
0%
1
9999
266
180
Control Mode-based Correspondence
Instruction Code
[Pr.]
Option
V/F control
306
06
86
3
307
07
87
3
308
08
88
3
309
09
89
3
310
0A
8A
3
311
0B
8B
3
312
0C
8C
3
313
0D
8D
3
314
0E
8E
3
315
0F
8F
3
316
10
90
3
317
11
91
3
318
12
92
3
319
13
93
3
320
14
94
3
321
15
95
3
322
16
96
3
323
17
97
3
324
18
98
3
329
1D
9D
3
338
26
A6
3
339
27
A7
3
340
28
A8
3
342
2A
AA
3
343
2B
AB
3
345
2D
AD
3
346
2E
AE
3
349
31
B1
3
387
57
D7
3
388
58
D8
3
389
59
D9
3
390
5A
DA
3
391
5B
DB
3
392
5C
DC
3
450
32
B2
4
180
PARAMETER
Table
General-
Advanced
purpose
magnetic
magnetic-
flux vector
flux vector
control
control
×
×
×
*9
*9
*9
*9
*9
*9
×
×
×
*9
*9
*9
*9
*9
*9
2

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fr-e700Fr-d700Fr-f700

Table of Contents