Vector Control Dedicated Motor - Mitsubishi Electric FR-A700 Technical Manual

Hide thumbs Also See for FR-A700:
Table of Contents

Advertisement

3.3.8

Vector control dedicated motor

Vector control dedicated motor is for full-scale vector control, and enables 100% of the continuous operation torque even at a
low speed.
Install a plug-in option for encoder feedback control (FR-A7AP or FR-A7AL) in
(1) Motor Type
1) Rated speed: 1500r/min (4 poles) (200V, 400V)
Standard
Model
type
Standard horizontal type*
Flange type*
Standard horizontal type
with brake*
Flange type with brake*
* Type name with H indicates 400V class. For example, when the model is standard horizontal type, use SF-V5RU
SF-V5RUH
for 400V class.
Standard
Model
type
Standard horizontal type
SF-THY
* Type of the 200V and 400V is the same.
2) Rated speed: 1000r/min (4 poles), maximum speed: 2000r/min speed ratio 1:2 (200V)
Standard
Model
type
Standard horizontal type
Flange type
Standard horizontal type
with brake
Flange type with brake
* 400V class models with the frame number 250 or higher are available as special products. Consult our sales office.
3) Rated speed: 1000r/min (4 poles), maximum speed: 3000r/min speed ratio 1:3 (200V)
Standard
Model
type
Standard horizontal type
Flange type
Standard horizontal type
with brake
Flange type with brake
* 400V class models with the frame number 250 or higher are available as special products. Consult our sales office.
4) Rated speed: 500r/min (4 poles), maximum speed: 2000r/min speed ratio 1:4 (200V)
Standard
Model
type
Standard horizontal type
Flange type
Standard horizontal type
with brake
Flange type with brake
* 400V class models with the frame number 250 or higher are available as special products. Consult our sales office.
Rated output (kW)
1.5
Frame Number
90L
100L 112M 132S 132M 160M 160M 180M 180M 200L 200L 200L 225S
SF-V5RU(H)
*
SF-V5RUF(H)
*
SF-V5RU(H)
B*
SF-V5RUF(H)
B*
Rated output (kW)
75
Frame Number
250MD 250MD 280MD 280MD 280MD
200V
*
400V
Rated output (kW)
1.5
2.2
Frame Number
100L 112M 132S 132M 160M 160L 180M 180L 200L 200L 225S
SF-V5RU
1
SF-V5RUF
1
SF-V5RU
1B
SF-V5RUF
1B
Rated output (kW)
1.5
2.2
Frame Number
112M 132S 132M 160M 160L 180M 180L 200L 200L 225S
SF-V5RU
3
SF-V5RUF
3
SF-V5RU
3B
SF-V5RUF
3B
Rated output (kW)
1.5
2.2
Frame Number
132M 160M 160L 180L 200L 225S 225S
SF-V5RU
4
SF-V5RUF
4
SF-V5RU
4B
SF-V5RUF
4B
A700
2.2
3.7
5.5
7.5
11
90
110
132
160
3.7
5.5
7.5
11
3.7
5.5
7.5
11
3.7
5.5
7.5
11
501
SELECTION
15
18.5
22
30
37
for 200V class, and
200
250
280L
315H
15
18.5
22
30
37
15
18.5
22
30
15
: Available —: Not available
45
55
3

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fr-e700Fr-d700Fr-f700