Mitsubishi Electric FR-A700 Technical Manual page 526

Hide thumbs Also See for FR-A700:
Table of Contents

Advertisement

4.1.3
The inverter equipped with magnetic contactor on primary side (with high-duty
brake resistor)
22K or less
A700
0.4K to 15K
E700
D700
Power
supply
Ready
"OFF"
"ON"
PB2
PB1
MC
Forward
Stop
rotation
MC
PB5
Reverse
rotation
Related parameter
Reset selection [Pr. 75]
*1
This magnetic contactor is provided to prevent an automatic restart when power is restored after a power failure. Use the start
signal (ON or OFF of STF, STR) to make a start or stop.
*2
When the power supply is 400V class, install a step-down transformer.
*3
Set [Pr. 75 = 1] "Reset input is enabled only when the fault occurs" to disable resetting of the inverter during normal operation. (If
the inverter is reset during normal operation, the motor coasts to a stop. This setting is to prevent the inverter from resulting in
an alarm if the motor is still coasting when the inverter has returned from the reset status.)
*4
When using an external brake resistor or brake unit, remove the jumper from across PR-PX.
(
7.5K or less only. Not available for
A700
Do not use PR and PX terminals for the
A700 E700 D700
(A700)
MCCB
*1
MC
T
*2
F
OCR
M
C
PB3
R
F
F
PB4
F
R
R
Hz
Frequency meter
Moving-coil type 1mA
F
R
Frequency setting
potentiometer
2W1k
E700
. Do not remove the jumper connected to terminal PR and PX.)
F700
Inverter
R
U
S
V
T
W
C
Ground
B
Thermal relay
P
*4
PX
PR
FM
Reset
PB6
SD
RES
STF
SD
STR
10
2
5
.
D700
560
PRACTICAL CIRCUITS
Motor
IM
High-duty brake resistor
OCR
R
*3

Hide quick links:

Advertisement