Mitsubishi Electric FR-A700 Technical Manual page 106

Hide thumbs Also See for FR-A700:
Table of Contents

Advertisement

Name
The inverter trips if an earth (ground) fault
Output side earth
overcurrent flows due to an earth (ground)
(ground) fault
fault that occurred on the inverter's output
overcurrent
side (load side).
The inverter trips if [Pr. 249 Earth (ground)
fault detection at start] is set active (=1) and
Output side earth
an earth (ground) fault overcurrent flows at
(ground) fault
start due to an earth (ground) fault that
overcurrent at start
occurred on the inverter's output side (load
side).
If the external thermal relay provided for
motor overheat protection or the internally
External thermal
mounted temperature relay in the motor, etc.
relay operation
switches ON (contacts open), the inverter
output is stopped.
For
A700 F700
motor overheat status is detected for 10s or
more by the external PTC thermistor input
PTC thermistor
connected to the terminal AU.
operation
For
, inverter trips when resistance of
D700
PTC thermistor connected between terminal
2 and terminal 10 is more than the value set
in [Pr.561 PTC thermistor protection level].
Appears when the AC power supply is
connected to the terminal R/L1, S/L2, T/L3
accidentally when a high power factor
converter is connected.
Appears when the switch for the
manufacturer setting of the plug-in option is
Option fault
changed.
For
, it appears when torque
A700
command by the plug-in option is selected
using [Pr. 804 Torque command source
selection] and no plug-in option is mounted.
Stops the inverter output when a
Communication
communication line fault occurs in the
option fault
communication option.
Stops the inverter output if a contact fault or
the like of the connector between the
inverter and built-in option occurs or if a
communication option is fitted to the
Option fault
connector 1 or 2 (
Appears when the switch for the
manufacturer setting of the plug-in option is
changed.
Control
circuit board
Appears when a fault occurred in
parameters stored (EEPROM failure)
Main circuit
board
When a combination of control board and
Internal board fault
main circuit board is wrong, the inverter is
tripped.
Description
Operation
, the fault appears when the
only).
A700
99
Indication
Parameter unit
panel
FR-PU04 FR-PU07
Ground Fault
(E.GF)
Ground Fault
(E.GF)
OH Fault
(E.OHT)
PTC
Fault 14
activated
(E.PTC)
Option Fault
(E.OPT)
Option1 Fault
(E.OP1)
Option3 Fault
(E.OP3)
Fault 1
(E.1)
Fault 2
(E.2)
Fault 3
(E.3)
Corrupt Memry
(E.PE)
PR
Fault 14
storage
(E.PE2)
alarm
PR
Fault 14
storage
(E.PE2)
alarm