Mitsubishi Electric FR-A700 Technical Manual page 12

Hide thumbs Also See for FR-A700:
Table of Contents

Advertisement

Type FR-F740-
K
Applicable motor capacity
(kW)
*1
Rated capacity (kVA)
*2
Rated current (A)
*3
Overload current rating
*4
Voltage
*5
Regenerative
Maximum value/
braking torque
permissible duty
Rated input AC voltage/
frequency
Permissible AC voltage
fluctuation
Permissible frequency
fluctuation
Power supply
Without DC
system
reactor
capacity
With DC
(kVA)
reactor
*6
Protective structure (JEM
1030)
*8
Cooling system
Approximate mass (kg)
*1
The applicable motor capacity indicated is the maximum capacity applicable for use of the Mitsubishi 4-pole standard motor.
*2
The rated output capacity indicated assumes that the output voltage is 220V for 200V class and 440V for 400V class.
*3
When operating the inverter with the carrier frequency set to 3kHz or more, the carrier frequency will automatically decrease
if the output current of the inverter exceeds the value in parenthesis of the rated current. This may cause the motor noise to
increase.
*4
The % value of the overload current rating indicated is the ratio of the overload current to the inverter's rated output current.
For repeated duty, allow time for the inverter and motor to return to or below the temperatures under 100% load.
*5
The maximum output voltage does not exceed the power supply voltage. The maximum output voltage can be changed
within the setting range. However, the pulse voltage value of the inverter output side voltage remains unchanged at about
that of the power supply.
*6
The power supply capacity varies with the value of the power supply side inverter impedance (including those of the input
reactor and cables).
*7
When the hook of the inverter front cover is cut off for installation of the plug-in option, the inverter changes to an open type
(IP00).
*8
FR-DU07 : IP40 (except for the PU connector)
75
90
110
132
160
75
90
110
132
160
110
137
165
198
247
144
180
216
260
325
(122)
(153)
(183)
(221)
(276)
120% 60s, 150% 3s (inverse-time characteristics)
110
137
165
198
247
37
50
57
72
72
185
220
250
280
315
185
220
250
280
315
275
329
366
416
464
361
432
481
547
610
(306)
(367)
(408)
(464)
(518)
Three-phase 380 to 480V
10% torque/continuous
Three-phase 380 to 480V 50Hz/60Hz
323 to 528V 50Hz/60Hz
±5%
275
329
366
416
464
Open type (IP00)
Forced air cooling
110
110
175
175
175
5
SPECIFICATIONS
355
400
450
500
355
400
450
500
520
586
659
733
683
770
866
962
(580)
(654)
(736)
(817)
520
586
659
733
260
260
370
370
560
560
833
1094
(929)
1
833
370

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fr-e700Fr-d700Fr-f700

Table of Contents