Function Diagnosis (H08 or 08)
A communication check can be made since the
query message sent is returned unchanged as a
response message (function of sub function code
H00).
Query message
1) Slave
2) Function
Address
H08
(8bit)
(8bit)
Normal response (Response message)
1) Slave
2) Function
Address
H08
(8bit)
(8bit)
• Query message setting
Message
1) Slave address
2) Function
3) Sub function
4) Data
• Description of normal response
1) to 4) (including CRC check) of the normal
response are the same as those of the query
message. For broadcast communication, no
response is returned in reply to a query.
Therefore, the next query must be made when
the inverter processing time has elapsed after
the previous query.
3) Sub function
4) Date
H00
H00
H
(8bit)
(8bit)
(8bit)
3) Sub function
4) Date
H00
H00
H
(8bit)
(8bit)
(8bit)
Set the address to which a message will be sent. Broadcast communication
cannot be made (0 is invalid).
Set H08.
Set H0000.
Any data can be set if it is 2 bytes long. The setting range is H0000 to HFFFF.
464
CRC Check
L
L
H
(8bit)
(8bit)
(8bit)
CRC Check
L
L
H
(8bit)
(8bit)
(8bit)
Setting Description