Mitsubishi Electric FR-A700 Technical Manual page 142

Hide thumbs Also See for FR-A700:
Table of Contents

Advertisement

[Pr.]
Name
C29
Motor temperature detection calibration
0 to 200%
(925)
(analog input)
*7
C30
Terminal 6 bias frequency (speed)
0 to 400Hz
(926)
*7
C31
Terminal 6 bias (speed)
0 to 300%
(926)
*7
C32
Terminal 6 gain frequency (speed)
0 to 400Hz
(927)
*7
C33
Terminal 6 gain (speed)
0 to 300%
(927)
*7
C34
Terminal 6 bias command (torque)
0 to 400%
(928)
*7
C35
Terminal 6 bias (torque)
0 to 300%
(928)
*7
C36
Terminal 6 gain command (torque)
0 to 400%
(929)
*7
C37
Terminal 6 gain (torque)
0 to 300%
(929)
*7
C38
Terminal 4 bias command (torque/magnetic
0 to 400%
(932)
flux)
*7
C39
Terminal 4 bias (torque/magnetic flux)
0 to 300%
(932)
*7
C40
Terminal 4 gain command (torque/magnetic
0 to 400%
(933)
flux)
*7
C41
Terminal 4 gain (torque/magnetic flux)
0 to 300%
(933)
*7
989
Parameter copy alarm release
10, 100
990
PU buzzer control
0, 1
991
PU contrast adjustment
0 to 63
Pr.CL Parameter clear
0, 1
ALLC All parameter clear
0, 1
Er.CL Faults history clear
0, 1
PCPY Parameter copy
0, 1, 2, 3
*1
Differ according to capacities. (0.4K
0.75K/1.5K to 3.7K/5.5K
,
*2
Differ according to capacities. (55K or less/75K or more)
*3
Differ according to capacities. (7.5K or less/11K or more)
*4
Differ according to capacities. (7.5K or less/11K to 55K/75K or more)
*5
The initial value differs according to the voltage class. (200V class/400V class)
*6
Can be read and written by only communication from the PU connector.
*7
The parameter number in parentheses is the one for use with the parameter unit (FR-PU04/FR-PU07).
*8
These parameters are communication parameters that are not cleared when parameter clear (all clear) is executed from RS-
485 communication. (Refer to page 441 for RS-485 communication)
PARAMETER
Minimum Setting
Refer to
Setting Range
Initial Value
Increments
0.1%
100%
0.01Hz
0Hz
217, 304
0.1%
0%
217, 304
0.01Hz
60Hz
217, 304
0.1%
100%
217, 304
0.1%
0%
0.1%
0%
0.1%
150%
0.1%
100%
0.1%
0%
0.1%
20%
0.1%
150%
0.1%
100%
1
10/100
*2
1
1
1
58
1
0
1
0
1
0
1
0
7.5K/11K to 55K/75K or more)
,
150
[Pr.]
Option
Page
C29
50
(925)
C30
(926)
C31
(926)
C32
(927)
C33
(927)
C34
320
(928)
C35
320
(928)
C36
320
(929)
C37
320
(929)
C38
320
(932)
C39
320
(932)
C40
320
(933)
C41
320
(933)
989
389
990
389
991
Pr.CL
ALLC
Er.CL
PCPY
Instruction Code
Control Mode-based Correspondence Table
Advanced
Vector control
magnetic
flux
vector
control
19
99
9
1A
9A
9
1A
9A
9
1B
9B
9
1B
9B
9
×
×
1C
9C
9
×
×
1C
9C
9
1D
9D
9
×
×
×
×
1D
9D
9
20
A0
9
×
×
×
×
20
A0
9
21
A1
9
×
×
×
×
21
A1
9
59
D9
9
5A
DA
9
5B
DB
9
FC
FC
F4
150
PARAMETER
Real sensorless
vector control
Speed
Torque
control
control
×
×
×
×
×
×
×
×
×
×
×
2
×
×
×
×

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fr-e700Fr-d700Fr-f700