Mitsubishi Electric FR-A700 Technical Manual page 19

Hide thumbs Also See for FR-A700:
Table of Contents

Advertisement

(3) FR-E700
Control method
Output frequency range
Frequency setting
Analog input
resolution
Digital input
Analog input
Frequency accuracy
Digital input
Voltage/frequency characteristics
Starting torque
Torque boost
Acceleration/deceleration time setting
Regenerative∗1
Braking torque
DC injection brake Operation frequency (0 to 120Hz), operation time (0 to 10s), operation voltage (0 to 30%) variable
Stall prevention operation level
Frequency setting
Analog input
signal
Digital input
Start signal
Input signal
Operational functions
Open collector
Output signal
output
points
Relay output
Operating status
Output point for
Pulse output
meter
For meter
Operation panel
Operating status
Parameter unit (FR-
PU07)
Fault definition
Additional display by
Operating status
Fault definition
the parameter unit
Interactive
(FR-PU04/FR-PU07)
guidance
only
Soft-PWM control/high carrier frequency PWM control (V/F control, Advanced magnetic flux vector control,
General-purpose magnetic flux vector control, Optimum excitation control can be selected)
0.2 to 400Hz
0.06Hz/60Hz (terminal2, 4: 0 to 10V/10bit)
0.12Hz/60Hz (terminal2, 4: 0 to 5V/9bit)
0.06Hz/60Hz (terminal4: 0 to 20mA/10bit)
0.01Hz
Within ±0.5% of the max. output frequency (25°C ±10°C)
Within 0.01% of the set output frequency
Base frequency can be set from 0 to 400Hz, constant-torque/variable torque pattern can be selected
200% or more (at 0.5Hz)...when Advanced magnetic flux vector control is set (3.7K or less)
Manual torque boost
0.01 to 360s, 0.1 to 3600s (acceleration and deceleration can be set individually), linear or S-pattern acceleration/
deceleration mode can be selected.
0.1K, 0.2K ..... 150%,
0.4K, 0.75K ..... 100%,
1.5K ..... 50%,
2.2K or more ..... 20%
Operation current level can be set (0 to 200% adjustable), whether to use the function or not can be selected
Two points
Terminal 2: 0 to 10V, 0 to 5V can be selected
Terminal 4: 0 to 10V, 0 to 5V, 4 to 20mA can be selected
Entered from operation panel and parameter unit
Forward and reverse rotation or start signal automatic self-holding input (3-wire input) can be selected.
Seven points
You can select from among multi-speed selection, remote setting, stop-on contact selection, second function
selection, terminal 4 input selection, JOG operation selection, PID control valid terminal, brake opening
completion signal, external thermal input, PU-External operation switchover, V/F switchover, output stop, start
self-holding selection, forward rotation, reverse rotation command, inverter reset, PU-NET operation switchover,
External-NET operation switchover, command source switchover, inverter operation enable signal, and PU
operation external interlock
Maximum/minimum frequency setting, frequency jump operation, external thermal relay input selection,
automatic restart after instantaneous power failure operation, forward/reverse rotation prevention, remote setting,
brake sequence, second function, multi-speed operation, stop-on contact control, droop control, regeneration
avoidance, slip compensation, operation mode selection, offline auto tuning function, PID control, computer link
operation (RS-485)
Two points
One point
You can select from among inverter operation, up-to-frequency, overload alarm, output frequency detection,
regenerative brake prealarm, electronic thermal relay function prealarm, inverter operation ready, output current
detection, zero current detection, PID lower limit, PID upper limit, PID forward/reverse rotation output, brake
opening request, fan alarm∗3, heatsink overheat pre-alarm, deceleration at an instantaneous power failure, PID
control activated, during retry, life alarm, current average value monitor, remote output, alarm output, fault output,
fault output 3, and maintenance timer alarm
MAX 2.4kHz: one point
You can select from among output frequency, motor current (steady), output voltage, frequency setting, motor
torque, converter output voltage, regenerative brake duty, electronic thermal relay function load factor, output
current peak value, converter output voltage peak value, reference voltage output, motor load factor, PID set
point, PID measured value, output power
Pulse train output (1440 pulse/s/full scale)
You can select from among output frequency, motor current (steady), output voltage, frequency setting,
cumulative energization time, actual operation time, motor torque, converter output voltage, regenerative brake
duty, electronic thermal relay function load factor, output current peak value, converter output voltage peak value,
motor load factor, PID set point, PID measured value, PID deviation, inverter I/O terminal monitor, I/O terminal
option monitor, output power, cumulative power, motor thermal load factor, and inverter thermal load factor.
Fault definition is displayed when the fault occurs and the past 8 fault definitions (output voltage/current/
frequency/cumulative energization time right before the fault occurs) are stored
Not used
Output voltage/current/frequency/cumulative energization time immediately before the fault occurs
Function (help) for operation guide
12
SPECIFICATIONS