Mitsubishi Electric FR-A700 Technical Manual page 389

Hide thumbs Also See for FR-A700:
Table of Contents

Advertisement

(1) Connection example
MCCB
Three-phase
AC power
supply
Forward rotation start
Reverse rotation start
Orientation command
Contact input common
*1
For the fan of the 7.5kW or less dedicated motor, the power supply is single phase.
*2
The pin number differs according to the encoder used.
*3
Use [Pr. 178 to Pr. 189 Input terminal function selection] to assign the function to any of terminal (refer to page 37).
*4
Use [Pr. 190 to Pr. 196 Output terminal function selection] to assign the function to any of terminal (refer to page 61).
*5
The encoder should be coupled on the same axis with the motor shaft without any mechanical looseness. Speed ratio should be 1:1.
*6
Earth (Ground) the shielded cable of the encoder cable to the enclosure with a P clip, etc. (refer to page 91).
*7
For the differential line driver, set the terminating resistor selection switch to ON position (initial status) to use (refer to page
86). Note that the terminating resistor switch should be set to OFF position when sharing the same encoder with other unit
(NC, etc.) and a terminating resistor is connected to other unit.
For the complementary, set the switch to OFF position.
*8
Refer to page 88 for terminal compatibility of the FR-JCBL, FR-V5CBL, FR-A7AP, and FR-A7AL.
*9
A separate power supply of 5V/12V/15V/24V is necessary according to the encoder power
specification.
When performing encoder feedback control and vector control together, an encoder and
power supply can be shared.
*10 When a stop position command is input from outside, a plug-in option FR-A7AX is
necessary. Refer to page 424 for external stop position command.
*11 Assign OH (external thermal input) signal to the terminal CS.
([Pr. 186 = 7])
Connect a 2W1k
resistor between the terminal PC and CS (OH).
Install the resistor pushing it against the bottom part of the terminal block so as to avoid a
contact with other cables.
(2) Setting I/O signals
Terminal
Terminal Name
Orientation
X22
command input
Contact input
SD
common
Orientation complete
ORA
signal output
Orientation fault
ORM
signal output
Open collector
SE
output common
SF-JR motor with encoder
Inverter
R/L1
U
S/L2
V
W
T/L3
STF
Earth (Ground)
FR-A7AP
STR
PA1
X22
*3
PA2
SD
PB1
ORA
*4
PB2
ORM
*4
PZ1
SE
PZ2
Differential
SD
PG
FR-A7AX
SD
Complementary
*10
X15
PG
X14
Terminating
SD
*6
resistor ON
X1
(+)
(-)
*8
X0
*7
DY
OFF
Used to enter an orientation signal for orientation.
For the terminal used for X22 signal input, set 22 in any of [Pr. 178 to Pr. 189] to assign the function.
Common terminal for the orientation signal.
Switched low if the orientation has stopped within the in-position zone while the start and orientation
signals are input.
For the terminal used for the ORA signal output, assign the function by setting 27 (positive logic) or
127 (negative logic) in any of [Pr. 190 to Pr.196].
Switched low if the orientation has not stopped within the in-position zone while the start and
orientation signals are input.
For the terminal used for the ORM signal output, assign the function by setting 28 (positive logic) or
128 (negative logic) in any of [Pr.190 to Pr.196] .
Common terminal for the ORA and ORM open collector output terminals.
423
For complementary type
MCCB
*1
Three-phase
U
AC power
supply
V
IM
W
Inverter
U
E
V
W
C
*2
External
PC
R
thermal relay
input
*11
CS(OH)
A
SD
N
FR-A7AP
PA1
Encoder
B
PA2
P
*5
PB1
PB2
H
PZ1
Differential
K
PZ2
PG
Complementary
SD
Terminating
PG
resistor ON
5VDC power
SD
supply
*9
*8
*7
OFF
Application Explanation
PARAMETER
(SF-V5RU)
SF-V5RU
A
B
FAN
C
U
V
IM
W
E
Earth (Ground)
Thermal
2W1kΩ
relay
G1
protector
G2
*2
A
B
C
D
Encoder
F
G
*5
S
R
*6
(-)
(+)
12VDC power
supply
*9
CS (OH)
PC
Control circuit
terminal block
Resistor (2W1kΩ)
2